background image

4

Operation of the fire – continued

this position (keeping it depressed) for ten seconds to allow the flame supervision
device to establish.

Observe if it is alight by looking through the slots to the left hand end of the front
coals.

If the pilot does not light immediately, repeat the above procedure, keeping the knob
depressed for several seconds in order to purge any air from the system.

If after ten seconds, ignition has not occurred, turn the control knob back to the OFF
position and repeat the ignition procedure after 30 seconds.

Once the pilot is lit, keep the control knob depressed for ten seconds to allow the
flame supervision device to establish.

When the control knob is released, the pilot should remain lit. If the pilot fails to
remain lit, repeat the ignition procedure, this time keeping the control knob
depressed for a longer period of time.

Lighting the Main Burner

Once the pilot light is established, the main burner can be lit by turning the pilot
burner control knob anti-clockwise to position 3 (refer to figure 3), and by then
turning the main burner control knob to the ‘high’ position (5).

Controlling the heat setting.

In order to change from one setting to another turn the main burner control knob to
the required position.  Alternatively, if a setting between LOW (4) and HIGH (5) is
required, then the control knob may be turned to this position.

Note: We recommend you use the appliance at a low setting for the first few hours of
use to reduce the thermal cracking of the surface of the burner.
Surface cracking of the burner is normal and is no cause for concern. Whist binding
materials are being burnt out of the burner there may be a slight odour.

To Turn the Fire back to Pilot Setting

Turn the main burner control knob fully clockwise. Alternatively turn the pilot burner
control knob clockwise to the ignition position (2). Refer to figure 3.

To Turn the Fire off

Rotate the pilot/burner control knob clockwise to position 1, as shown in figure 3.

Using the Remote Control Handset

When the pilot burner control knob is in position 3, the remote control handset may
be used to vary the flame effect between ‘High’ and ‘Low’, or switch the fire back to
pilot setting.

The handset operates on ultrasonic principles, and as such it is not necessary to
point the handset directly at the fire.

Summary of Contents for airflame excel mk.3 16NV RC

Page 1: ... RC 9500370 AC 16NV RC 9500371 AF 16XL RC 9500372 AC 16XL RC 9500373 USER MANUAL Patent applied for 9860378 03 Please leave these Instructions with the user This Appliance is for use in the United Kingdom GB and the Republic of Ireland IE only ...

Page 2: ...e If the appliance shuts down after a period of operation for no apparent reason then stop using the appliance until the installation and the appliance have been thoroughly checked by a competent person 11 Installation must be in accordance with the installation instruction and the rules in force 12 If the fire goes out for any reason wait at least three minutes before attempting to re light The H...

Page 3: ...fire This fire may be controlled manually by use of a gas valve mounted on the appliance The flame settings may also be controlled by means of the remote control handset To prevent accidental operation of the fire we recommend that the fire be switched off when not in use Light the Pilot Please note The fire must be lit manually Ensure that the pilot burner control knob is in the OFF position 1 De...

Page 4: ...urning the main burner control knob to the high position 5 Controlling the heat setting In order to change from one setting to another turn the main burner control knob to the required position Alternatively if a setting between LOW 4 and HIGH 5 is required then the control knob may be turned to this position Note We recommend you use the appliance at a low setting for the first few hours of use t...

Page 5: ... pilot alight turn the pilot burner control knob to the ignition position 2 Refer to figure 3 Battery Life Replacement Please note In order to ensure maximum battery life and optimal performance we recommend that only Long Life type replacement batteries are used Handset The remote control handset is powered by 1 x PP3 battery which should be replaced approximately every 12 months To replace Remov...

Page 6: ...which may have built up after prolonged use of the minimum aerated setting Cleaning Note Before attempting any of the following ensure that the fire has been allowed to cool completely Note Some discoloration of the coals is normal The cast parts of the fire should be carefully cleaned with a lint free damp cloth On no account should any metal polish or similar be used as this may prove harmful to...

Page 7: ...re 15 x Random cut coals Keep the different types of coals separate Begin the coal build by placing a square coal in the centre of the front coal ensuring that it bridges across to the matrix as shown in figure 10 Next take four random coals and place along the front coal as shown in figure 11 Again ensure that these coals bridge across from the front coal to the matrix In order to get the best fl...

Page 8: ...ld rest on top of the first row overlapping by 5 10mm Again ensure even spacing to obtain the best flame effect NG MODELS ONLY Next take five random shaped coals and arrange as shown in figure 14 Again these coals should overlap the previous row by 5 10mm Once again ensure even spacing LPG MODELS ONLY Take three random coals and position in the centre of the matrix spaced 10 15mm from each other t...

Page 9: ...Description Part Number Front coal 9770085 Coal matrix 9770084 Pack of dress coals 9780043 LPG MODELS NOT REQUIRED GUARANTEE Every Wonderfire product is warranted for a period of twelve months against manufacturing faults Any part found to be of substandard quality will be replaced free of charge by your supplier upon receipt of the original purchase receipt The Guarantee does not extend to cover ...

Page 10: ...epartment If you require your fire to be serviced or in the unlikely event that it should require repair due to a manufacturing defect then call Wonderfire service department on 0121 386 6203 quoting your details listed below From the Republic of Ireland call 00 44 373 8111 for all enquiries Model WONDERFIRE AIRFLAME EXCEL MK 3 16 REMOTE CONTROL Model number See data label Suppliers name Suppliers...

Reviews: