103
The description of the columns is as below:
System Event Selection
Warning Event is sent when…..
Device Cold Start
Power is cut off and then reconnected.
Device Warm Start
Reboot the device by CLI or Web UI.
Authentication failure
An incorrect password, SNMP Community String is entered.
Time Synchronize Failure
Accessing to NTP Server is failure.
Power 1/ 2 Failure
The power input is failure.
Relay Output 1
The Digital Output is on.
DI 1 Change
The Digital Input change
Ring Event
Ring Status has changed or backup path is activated.
SFP Event
The SFP transceiver’s state is abnormal.
Port Event
Warning Event is sent when…..
Up
The port is connected to another device
Down
The port is disconnected (e.g. the cable is pulled out, or the opposing devices
turns down)
Both
The link status changed.
3.11.3 SYSLOG SETTING
System Log is useful to provide system administrator locally or remotely monitor switch events history. There are 3
System Log modes provided by the switch, local mode, remote mode and both.
Local Mode
: In this mode, the device will print the occurred events selected in the Event Selection page to System
Log table of the switch. User can monitor the system logs in [Diagnostics] / [Syslog Setting] page.
Remote Mode
: The remote mode is also known as Server mode in WoMaster managed switch. In this mode, User
should assign the IP address of the System Log server. The switch will send the occurred events selected in Event
Selection page to System Log server User assigned.
Both:
Above 2 modes can be enabled at the same time.
Once User finishes configuring the settings, click on
Submit
to apply User configuration. When enabling Local or
Both modes, User can monitor the system logs in [Diagnostics] / [Event Log] page