background image

For regular use of the WolfVision Visualizer, it is not necessary to go into the Visualizer's menu and change 
settings. Inexperienced users should not make any adjustments here.

To enter the on-screen menu keep pressed the MENU

 

key

 

(EXTERN #10)

 for 1 second. Settings of the 

Visualizer's basic functions and the built-in camera can be made here using the navigation keys 

or the ZOOM wheel

he camera head. To enter the selected sub menu or 

changing the selected value/digit use the ENTER ke

 Selection keys 

(LIGHT #11 

and FOCUS 

 to indicate the second function of the keys.

To get more information of a function in the on-screen menu

,

 set the cursor in the respective line and press 

the HELP key 

(press and hold FREEZE #12). 

A detailed description of this function appears on the screen.

   

By pressing the MENU

 

key for 4 seconds the Extra Menu appears. 

In the Extra Menu, settings like ZOOM wheel calibration can be performed.

 

   

   

The functions of the on-screen menu are not described in detail in this user manual as the help menu is an 
integrated part of the Visualizer's software (firmware). The information you see on your screen always 
belongs to the current Visualizer firmware. 

(FREEZE 

#12 and EXTERN #10)

 

 

(#13)

 on t

(POWER #15)

 and the

#14)

. As long as the on-screen menu is activated, the arrows beside the keys on the camera 

are flashing

In  the  "Power  Control"  settings  of  the  on-screen  menu  you  can  select  that  the  Visualizer  will  be 
automatically switched off after a certain amount of time.

All settings in the on-screen menu can be set back to the factory defaults. "Recall Default Settings" is one 
item in the on-screen menu.

Please note, settings which affect the output and communications ports are not affected to prevent un-
supported resolutions or loosing data link.

The following chapter is for experienced users only:

ON-SCREEN MENU / ON-SCREEN HELP

Changing the Color Settings

Auto Power-off

RESET OF ON-SCREEN MENU SETTINGS

10

If the picture on your screen appear to be too light or too dark or the color saturation is not correct, you can 
change the Color Mode in the on-screen menu (Color Settings). Pre-settings are PRESENTATION (higher 
color saturation), NATURAL (sRGB) and VIDEO CONF (for video conferencing systems).
Alternative Gamma and Saturation can be changed manually.

The output image of the Visualizers can be switched from positive to negative in the on-screen menu. In 
addition, the background of a negative image can be switched to blue for better readability of text. You can 
also switch between color or black and white in the on-screen menu.

Switching to Negative, Negative/Blue and Black/White

Text Mode

For improving the readability of text, sketches or x-rays, the text mode can be activated in the on-screen 
menu, Color Settings. 
This mode enhances the contrast of the picture. Please note that the colors are now 

darker than usual

.

Open „Device Info” in the sub menu „Advanced Settings” to view details of the unit.

Device information und Firmware version

Summary of Contents for VZ-3

Page 1: ...Check out our Internet Homepage for additional information www wolfvision com support VZ 3 INSTRUCTIONS INSTRUCTIONS ENGLISH R VZ 3 ...

Page 2: ...or damage to the CCD camera Do not pull the plug from the power socket with wet hands If the Visualizer is not used for a long time disconnect it from mains The external power supply has to be approved by CSA or UL in accordance to CSA 22 2 60950 or UL1950 One PushWhiteBalance Pressthe LIGHTkey for 2 secondsto performone push whitebalance Activatingthe on screenmenu Keep the MENU key EXTERN presse...

Page 3: ...nt Inspections tests and evaluation are according to UL60950 CSA22 22 60950 Inspections tests and evaluation are according to the CB Scheme Inspections tests and evaluation are according to the PCT Scheme Marks on the unit Approval Copyright Information Copyright by WolfVision All rights reserved WolfVision Wofu Vision and are registered trademarks of WolfVision HoldingAG Austria No part of this d...

Page 4: ...ectors on the back behind the cable cover see below Zoom wheel see next page 3 Connectors 2 5 DVI I output see page 8 6 USB port see page 7 External Input for Computer RGB signals 15pin 10 100 TBase 7 see page 9 8 LAN port see page 7 Power connection PoE see page 7 9 Cable Tie to fix all cables to unfasten press the lug 5 LAN PoE EXTERN IN USB DVI 6 8 7 9 ...

Page 5: ...essed for 2 seconds 13 ZOOM WHEEL menu navigation wheel up and down Turn the wheel down to zoom in TELE and up to zoom out WIDE The more you turn the ZOOM WHEEL the faster the zooming works When the on screen menu is activated it functions as navigation wheel to navigate up and down see page 10 14 FOCUS key menu select key right Switches the auto focus on and off The arrow beside the key indicates...

Page 6: ... cover 2 Connect the power pack to the power input 8 3 Connect your display device projector monitor video conferencing unit etc to the appropriate output of the Visualizer 5 RGB with adapter and fasten the cable tie IMPORTANT For choosing the right output setting please read the detailed description on page 8 4 Slide in cable cover until it rasted 5 Lift the arm upwards The VZ 3 is switched on au...

Page 7: ...white balance of the Visualizer at first and if the results are still not satisfactory the monitor or projector should be checked This means that the white balance is continuously adjusted automatically White Balance Adjustment 6 IMPORTANT Please note that the Visualizer has an optical 12x zoom The digital 2x zoom increases the overall zoom range to a 24x zoom The smallest pickup size on the worki...

Page 8: ...hem to Interactive Whiteboards Smart Boards The fast USB 2 0 port can also output live motion WolfVision s Connectivity Software can store AVI files and includes a video capture driver You can view and save the live image from the Visualizer on your computer in almost every modern video editing software Please download the latest version of the WolfVision Connectivity Software from www wolfvision ...

Page 9: ...fresh rate than your monitor or projector can display otherwise the monitor or projectorcan be damaged Follow the instructionsin the user manual of the connectedunits Please note if 4 3 and 16 9 or 16 10 resolutions are used simultaneously the 4 3 display shows black bars on top and bottom This is necessaryto ensure that all displaysshow the same image content The Auto resolution function is activ...

Page 10: ...0kHz 121kHz Maximum pixel clock 170MHz Gamma 2 2 Preferred resolution SXGA 1280x960 60Hz pressing the EXTERN key 10 The settings of the Visualizer can be changed in the on screen menu see page 10 Use supplied cable without choke ferrit core other cables may block the hinge mechanically Built in Digital Scaler for Extern In The Visualizer has a built in digital image scaler which can process the si...

Page 11: ...can select that the Visualizer will be automatically switched off after a certain amount of time All settings in the on screen menu can be set back to the factory defaults Recall Default Settings is one item in the on screen menu Please note settings which affect the output and communications ports are not affected to prevent un supported resolutions or loosing data link The following chapter is f...

Page 12: ...TENANCE The software firmware of your Visualizer including the o can easily be upgraded to the latest version The firmware update can be done via USB or Ethernet LAN Firmware update files can be downloaded for free at www wolfvision com support Updates can be performed with the WolfVision Connectivity Software This software can be found under the same link as the firmware files n screen HELP Firmw...

Page 13: ...be required Drill a whole into the table on the desired position Ø 42mm 1 65 1 Fold the unit to remove the cover 2 Remove the original base plate by removing both screws keep it for further use 3 Place one adapter plate and both screws M4x50 Torx20 and fix it with at least one nut Place the necessary cables and connect it begin with the biggest connector depending on installation place the cables ...

Page 14: ... consumption external power pack Operating Temperature Relative Humidity Warranty Made in 1 CCD 1 3 Progressive Scan Camera 30 frames 1280 x 960 1 228 800 1 315 648 36 864 000 very good colors SXGA 1280x960 WXGA 1280x800 HD 720p 1280x720 SXGA WXGA 720p WXGA XGA switchable 710 lines Progressive Scan 50 Hz and 60Hz switchable automatic manual flickerless Shutter automatic and manual yes continuously...

Page 15: ...Co Ltd Tokyo Tel 81 0 3 3360 3231 Fax 81 0 3 3360 3236 E mail wolfvision japan wolfvision com United Kingdom WolfVision UK Limited Manchester Tel 44 161 435 6081 Fax 44 161 435 6100 E Mail wolfvision uk wolfvision com Toll free Tel 1 650 648 0002 Toll free 800 356 WOLF Fax 1 650 648 0009 Japan Asia WolfVision Asia Singapore Tel 65 6366 9288 65 6366 9280 E mail info wolfvisionasia com R Manufacture...

Reviews: