Sealed Burner Rangetop Specifications
7
wolfappliance.com/specs
IMPORTANT NOTE:
You must follow all National Electrical
Code regulations. In addition, be aware of local codes and
ordinances when installing your service.
IMPORTANT NOTE:
Reverse polarity will cause nuisance
clicking when power is turned on to the unit.
WIRING DIAGRAM
The wiring diagram covering the electrical circuit is
located on the inside left wall of the rangetop.
Electrical Requirements
The Wolf sealed burner rangetop requires a 110/120 V AC,
50/60 Hz electrical supply to operate the electronic
ignition system. The service should have its own 15 amp
circuit breaker. A ground fault circuit interrupter (GFCI)
is not recommended and may cause interruption of
operation.
The 6'
(1.8 m)
power cord is equipped with a 3-prong,
grounding plug for protection against shock hazard. The
power cord must be plugged into a mating 3-prong
grounded outlet, grounded to conform with the National
Electrical Code, ANSI/NFPA 70 latest edition, or Canadian
Electrical Code (CSA) and all local codes and ordinances.
Refer to the illustration below.
IMPORTANT NOTE:
This appliance must be properly
grounded to avoid electrical shock hazard. Do not ground
to a gas pipe.
GROUNDING
PLUG
GROUNDED
ELECTRICAL OUTLET
Electrical ground.
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove ground prong. Do not
use an adapter. Failure to follow these instructions can
result in electric shock, fire or death.