9
Dimensions in parentheses are in
millimeters unless otherwise specified.
I N S TA L L AT I O N
I N S T R U C T I O N S
H O O D
P R E P A R AT I O N
Follow these steps to prepare the wall chimney
hood for installation:
Remove the filters by pressing up at the
angle the filters are placed in, then rotate
the bottom of the filter down. Gloves
should be worn to provide proper grip.
Slide the grease cups out from the bottom
edges of the back of the hood.
Using a Phillips screwdriver, remove the
screws retaining the internal frame (shaded
area of the illustration below) to the hood.
Be careful not to remove the two other
screws
(refer to the illustration below).
Do not discard the screws.
They will be
reinstalled after installation of the hood is
complete.
Remove the internal frame from the hood
and set aside.
The hood assembly is shipped with the
transition attached. The transition is
shipped upside down in the top of the hood
and must be removed and reinstalled in the
proper position.
Separate the transition from the hood
assembly by removing the four shipping
screws. Invert and reattach the transition to
the hood with the shipping screws.
IMPORTANT NOTE:
If internal blower Model
CTBLOWER-60INT or CTBLOWER-90INT will be
used with the 36" (914) or 42" (1067) wide
hood, do not reinstall the transition yet.
If you are installing a remote blower, punch
out the knockout hole located on the top of
the hood. Install a wire clamp (included
with the hood) for remote blower cable.
Refer to the remote blower information on
page 16 and follow installation instructions
provided with the blower assembly.
Install one wire clamp (included with the
hood) in the hole on top of the hood for the
power cable.
Gre
as
e
C
u
p
S
IDE VIEW
Filter
S
pring
Intern
a
l fr
a
me
s
crew
s
loc
a
tion
Do not
remove
Do not
remove
Remove filters
Remove internal frame
Do not run wiring for the remote blower
through the ductwork.