I N S TA L L AT I O N
I N S T R U C T I O N S
H O O D
I N S T A L L A T I O N
IMPORTANT NOTE:
If an optional duct cover
is to be used with the Pro wall chimney hood,
it must be installed before installing the hood—
except for the 36" (914) and 42" (1067) wide
hoods with an internal blower. Refer to Duct
Cover Installation on page 10.
The filters and internal frame must be removed
from the hood prior to installation. Refer to
Hood Preparation on page 9.
Rest the top back cavity of the hood on the
wood mounting strip.
Holes to
reach wood
mounting strip
Upper slots
Back of wall hood
(inside view)
Lower slots
Hood installation
Using two #8 x 2" (51) screws provided—
four for 48" (1219) and 54" (1372) wide
hoods, secure the hood to the wood
mounting strip at the location shown in the
illustration below.
Using two #8 x 2" (51) screws and washers
provided, secure the top back of the hood
to the wall studs and/or blockings by the
upper slots. Then use three #8 x 2" (51)
screws and washers in the lower slots to
complete the installation of the hood to the
wall. Refer to the illustration below.
Connect the 10" (254) round ductwork to
the transition using sheet metal screws and
duct sealing tape.
If you are installing an internal blower, do
not reinstall the internal frame and filters
until the blower installation is complete.
Refer to Internal Blowers on page 15 and
follow installation instructions provided
with the blower.
Make electrical connections. Refer to Install
Wiring on pages 12–13.
Due to the weight of the hood, be sure
to have adequate manpower for installa-
tion.
Hold the hood until it is completely
secured to the wood mounting strip.