Component Access
Drawer Microwave
(Models MWD24-2 / MWD30-2)
4-7
#813632 - Revision B - December, 2009
Power Cord Replacement:
1.
Un-hook the black and white AC terminals from the
noise filter PWB and green ground wire from the
back plate (See Figure 4-7).
2.
Attach the black and white AC terminals from the
new power cord to the noise filter as shown in figure
4-7.
NOTE:
The green ground wire terminal can be attached
when reassembling the back plate to the drawer cavity.
Figure 4-7. Power Cord Replacement
White
Wire
Black
Wire
Cavity Light Replacement:
1.
Drawer Microwave must be removed from its instal-
lation. See Drawer Microwave Disassembly (page 4-
6) steps 1-3.
2.
Locate and remove lamp access panel in top plate
(See Figure 4-3 on page 4-6).
NOTE:
Lamp and socket are an assembly. You
must change socket along with the lamp.
3.
Remove lamp socket screw to remove the lamp
assembly and replace with new (See Figure 4-6).
Figure 4-6. Lamp & Socket Removal
Screw
Figure 4-5. Upper Components
Upper Cabinet Component Replacement: (Sensor,
Stirrer Motor, Upper Thermal Limiter)
1.
Drawer Microwave must be removed from its instal-
lation. See Drawer Microwave Disassembly (page 4-
6) steps 1-3.
2.
Wait 60 Sec. to discharge High Voltage Capacitor.
3.
Using a phillips screwdriver, remove the two mount-
ing screws (one on each side of the stirrer motor)
that fasten the stirrer motor assembly to the top of
the unit (See Figure 4-5).
NOTES:
•
The stirrer motor shaft has flat spots that must be
aligned with the stirrer fan assembly for reinstalla-
tion.
•
Please see “After Servicing” (Page 4-11) when
repair is complete.
Green
Ground Wire
Power
Cord
Stirrer
Motor
Screw
Black Plate