29
3065014_201612
Safety instructions
Please read the following installation and commissioning instructions carefully before
operating your appliance. This will avoid damage to your system which could arise
through incorrect handling.
Incorrect use and any unauthorised modifications made to the design or during
installation will result in any liability claims becoming void.
In addition to any applicable country-specific guidelines, the following engineering
standards must be observed.
DIN 1988
Drinking water supply systems
DIN 4708
Central water-based heating systems
EN 12828
Central heating systems in buildings – Designing hot water heating systems
DIN 4753
Water heaters and water heating installations for potable water and for service water
EN 12977
Thermal solar systems and components – Custom built systems
EN 12976
Thermal solar systems and components – Factory made systems
DIN 18380
Installation of central heating systems and hot water supply systems
DIN 18381
Installation of gas, water and drainage pipework inside buildings
DIN 18382
Cables and power lines in buildings
EN 12975
Thermal solar systems and components – Solar collectors
VDE 0100
Low voltage electrical installations
VDE 0185
Protection against lightning
Safety instructions
- Because of the control equipment, the entire system (DHW and heating water) must
be kept free of dirt (install dirt traps where necessary).
- Positioning and installation may only be carried out by an authorised contractor.
- The system must be installed in a location that is protected from frost.
- As with all DHW circulation systems, it is important to provide an appropriate excess
pressure facility or an expansion vessel.
- Observe all national codes for drinking water hygiene.
Notes:
Summary of Contents for FWS-2-80
Page 5: ...5 3065014_201612 Joogiveekeskus Ühenduskomplekt Paigalduskomplekt Tarnepakend ...
Page 15: ...15 3065014_201612 Primaarpumba PWM signaal 3 Hooldus ...
Page 16: ...16 3065014_201612 Segisti mootori vahetamine Hooldus ...
Page 19: ...19 3065014_201612 Hooldus ...
Page 31: ...31 3065014_201612 Freshwater module Connection set Installation set Standard delivery ...
Page 41: ...41 3065014_201612 PWM signal primary pump 3 Maintenance ...
Page 42: ...42 3065014_201612 Replacing the mixer motor Maintenance ...
Page 45: ...45 3065014_201612 Maintenance ...
Page 67: ...67 3065014_201612 Pirminio siurblio PWM signalas 3 Techninė priežiūra ...
Page 68: ...68 3065014_201612 Maišymo variklio keitimas Techninė priežiūra ...
Page 71: ...71 3065014_201612 Techninė priežiūra ...
Page 93: ...93 3065014_201612 PWM signāls primārajam sūknim 3 Tehniskā apkope ...
Page 94: ...94 3065014_201612 Jaucēja motora nomaiņa Tehniskā apkope ...