28.3. Preparing for maintenance
Removing the front casing
Screw
- First undo the central screw at the bottom of the front casing.
- Push in the two locking hooks at the bottom left and right and pull the casing
forwards.
- Lift the front casing upwards to release and remove it.
Isolating the system from the power supply
The mains terminals remain live even when
the ON/OFF switch has been switched OFF.
- Isolate the system from the power supply.
Closing the gas ball valve
Some components can be very hot. Let them cool down or wear
gloves.
Risk of burns
Seite 16