52
3064458_201811
Natural gas E/H 15,0:
W
S
= 11.4 - 15.2 kWh/m³ = 40.9 - 54.7 MJ/m³
Natural gas LL 12.4:
1)
W
S
= 9.5 - 12.1 kWh/m³ = 34.1 - 43.6 MJ/m³
LPG P
W
S
= 20.2 - 21.3 kWh/m³ = 72.9 - 76.8 MJ/m³
1)
not applicable in Austria / Switzerland
Table: Wobbe index subject to gas type
Gas categories and supply pressures
If the supply pressure is outside the specified range, no adjustments may be carried out and the boiler must not be started.
21. Determining the gas type
Setting the gas/air mixture
Carry out the adjustments in the order
described below.
The gas combination
valve has been set at the factory to the gas
type specified on the type plate. Only adjust
the gas combination valve after the system
has been changed to a different gas type.
Determining the gas type
The gas condensing boiler is equipped with a
pneumatic gas/air mixing facility. In the delivered
condition the boiler is set to natural gas E/H.
For operation with natural gas LL remove the gas
restrictor.
For operation with LPG P, replace the gas restrictor as
indicated in the table "Gas restrictors".
1. Request information regarding the gas type and
Wobbe index from your local gas supply utility or
LPG supplier.
2. For operation with natural gas LL and LPG P,
match the gas restrictor.
3. Enter the gas type in the commissioning report.
4. Open the gas ball valve.
Please note
Country of destination
Appliance category
Supply pressure in mbar
Natural
gas
LPG
Natural gas
LPG
nom.
min
max
nom.
min
max
DE
II2ELL3P
20
18
25
50
42,5
57,5
AT, LU
II2H3P
20
18
25
50
42,5
57,5
BE
I2ER
20/25
18
30
BE
I2ES
20/25
18
30
BE
I3P
37
25
45
BE
I3P
50
42,5
57,5
FR
II2Esi3P
20/25
17
25
37
25
45
FR
II2Esi3P
20/25
17
30
50
42,5
57,5
PL
II2ELw3P
20
18
25
37
25
45
TR
II2H3P
20
18
25
30/37
25
45
DK,EE, SI,
RO,MO,BG,CN,FI,NO,SE
II2H3P
20
18
25
30
25
35
CZ, IT,ES,GR,TR,HR,IE,SI
LT,LV,NO,PT,SE
II2H3P
20
18
25
37
25
45
CH,CZ,ES,GB,NO,SE
II2H3P
20
18
25
50
42,5
57,5
RU
II2H3P
20
13
25
30
50
25
42,5
35
57,5
UA
II2H3P
20
13
25
37
25
45
HU
II2H3P
20
18
25
37
25
45
HU
II2H3P
20
18
25
50
42,5
57,5
NL
II2L3P, II2EK3P
25
18
30
30/37
25
45
NL
II2L3P, II2EK3P
25
18
30
50
42,5
57,5