Page 32
GAS PRESSURE REFERENCE
GAS PRESSURE
Pressure
Value
Gas supply line pressure
Natural gas and liquid propane maximum
14" wc
Natural gas minimum
7" wc
Liquid propane minimum
11" wc
Natural gas manifold pressure
5" wc
Liquid propane manifold pressure
10" wc
ORIFICE QUICK REFERENCE CHART
Part Description
Part Number
Orifice Size
Part Number
Stamped
Size
Burner valve, 18K, Nat.
827463
Simmer
817308
62
.79 mm
Main
819770
67
.67 mm
Burner valve, 18K, LP
828043
Simmer
816465
43
.43 mm
Main
816465
43
.43 mm
Burner valve, 12K, Nat.
827462
Simmer
816788
50
.50 mm
Main
816731
57
.57 mm
Burner valve, 12K, LP
827486
Simmer
816538
33
.33 mm
Main
817372
38
.38 mm
Burner valve, 9.2K, Nat.
827466
Simmer
816788
50
.50 mm
Main
816610
54
.54 mm
Burner valve, 9.2K, LP
828132
Simmer
816538
33
.33 mm
Main
816823
34
.34 mm
Orifice holder, 20K, Nat.
826443
Simmer
817193
79
.79 mm
Main
824936
205
2.05 mm
Orifice holder, 20K, LP
826444
Simmer
817192
47
.79 mm
Main
824937
132
2.05 mm
Orifice holder, 18K, Nat.
823061
Simmer
817193
79
.79 mm
Main
824936
205
2.05 mm
Orifice holder, 18K, LP
823074
Simmer
817192
47
.47 mm
Main
824937
132
1.35 mm
Orifice holder, 12K, Nat.
819299
Simmer
816749
65
.65 mm
Main
816750
159
1.59 mm
Orifice holder, 12K, LP
824288
Simmer
817192
47
.47 mm
Main
819768
105
1.05 mm
Orifice holder, 9.2K, Nat.
819297
Simmer
816749
65
.65 mm
Main
816664
140
1.40 mm
Orifice holder, 9.2K, LP
819298
Simmer
817371
41
.41 mm
Main
817370
93
.93 mm
Note: Natural gas units installed over 9,900 ft may require a high altitude conversion kit.
CG Professional Gas Cooktop Service Manual
Technical Data
TECHNICAL DATA
service.subzero.com
828386 REV. A 06/2018