FIGURE 2 - GAS REGULATOR VENT
Regulator vent
Keep free of ice, snow,
and debris
H25.0.2
Most natural gas systems and all LP gas systems have a service regulator located near the point where the
gas piping enters the building.
The propane tank will normally have an additional fi rst stage regulator located at the tank outlet valve. All of
these regulators (located outdoors) will have a vent.
(Figure 2)
It is important for these vents to remain clear. Do not allow moisture, which could freeze, to build up in the vent.
If you see moisture building up in the regulator vent, contact your gas supplier.
H3.28
DEVICES ATTACHED TO EITHER THE VENT OR COMBUSTION AIR INTAKE FOR THE
PURPOSES OF EXCEEDING THE LIMITATIONS DESCRIBED IN THE INSTALLATION
MANUAL, INCLUDING FIELD INSTALLED INDUCED BLOWER FANS HAVE NOT BEEN
TESTED AND ARE NOT INCLUDED IN THE DESIGN CERTIFICATION OF THE FURNACE.
THE MANUFACTURER CANNOT AND WILL NOT SPECULATE ON THE EFFECTS OF
SUCH MODIFICATIONS AND CANNOT AND WILL NOT BE RESPONSIBLE FOR INJURY OR
DAMAGE CAUSED BY THE USE OF SUCH UNTESTED AND/OR UNCERTIFIED DEVICES,
ACCESSORIES OR COMPONENTS.
WARNING
!
!
H3.29
OBSTRUCTION OF THE AIR VENT ON AN LP (PROPANE) CYLINDER OR TANK REGULATOR
CAN CAUSE EXPLOSION OR FIRE RESULTING IN PROPERTY DAMAGE, SEVERE
PERSONAL INJURY OR DEATH.
YOUR GAS SUPPLIER SHOULD PERIODICALLY INSPECT AND CLEAN THE AIR VENT
SCREEN TO PREVENT ANY OBSTRUCTION. KEEP PROTECTIVE REGULATOR COVER IN
PLACE, AS EXPOSURE TO THE ELEMENTS CAN CAUSE ICE BUILDUP AND REGULATOR
FAILURE.
WARNING
!
!
W415-1245 / B / 03.19.15
UM
64
Summary of Contents for Continental C95 - B SERIES
Page 27: ...W415 1245 B 03 19 15 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES...
Page 28: ...W415 1245 B 03 19 15 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES...
Page 58: ...W415 1245 B 03 19 15 58 IOM IOM 23 0 SERVICE HISTORY 43 1...
Page 74: ...6 0 NOTES 44 1 W415 1245 B 03 19 15 UM 74...