13.0 CONVERSIONS
13.1 HIGH ALTITUDE CONVERSION
H18.1B
In Canada, this funace does not need to be converted for high altitude (2000-4500ft), when the fuel source
is natural gas. It has been certi
fi
ed to operate at high altitude as manufactured. If the fuel source is liquid
propane, refer to High Altitude Speci
fi
cations table for appropriate derate above 2000ft based on a 4%
reduction of input capacity for every 1000ft above sea level.
In the United States, this furnace does not need to be converted for high altitude from (2000-5400ft), when
the fuel source is natural gas. It has been certi
fi
ed to operate at high altitude as manufactured up to 5400ft
only. Beyond 5400ft the modi
fi
cations are based on a 4% reduction of input capacity for every 1000ft above
sea level. If the fuel source is liquid propane, refer to High Altitude Speci
fi
cations table for appropriate derate
above 2000ft based on a 4% reduction of input capacity for every 1000ft above sea level. Consult with local
fuel suppliers or authorities to determine local regulations or customs.
Input
K/Btu/hr
ALTITUDE
ORIFICE SIZE (DMS)
NATURAL
LP GAS
40/60/80
100/120
0-2000 (0-610 m)
45
55
2000-3000 (610-914 m)
56
3000-4000 (914-1219 m)
57
4000-5000 (1219-1524 m)
58
5000-5400 (1524-1646 m)
59
5400-6000 (1646-1829 m)
51
60
6000-7000 (1829-2134 m)
52
61
7000-8000 (2134-2438 m)
53
62
8000-9000 (2438-2743 m)
54
63
9000-10000 (2743-3048 m)
55
65
TABLE 6 - HIGH ALTITUDE SPECIFICATIONS
Gas input ratings are certifi ed for elevations to 5400 ft. (1646 m) on natural gas. For elevations above 5400 ft. (1646 m) on natural gas, or
LP fuel source above 2000 ft. (610 m), follow orifi ce derate chart above.
H12.8.1A
Input
K/Btu/hr
ALTITUDE
ORIFICE SIZE (DMS)
NATURAL
LP GAS
30
0-2000 (0-610 m)
50
57
2000-3000 (610-914 m)
58
3000-4000 (914-1219 m)
59
4000-5000 (1219-1524 m)
60
5000-5400 (1524-1646 m)
61
5400-6000 (1646-1829 m)
56
62
6000-7000 (1829-2134 m)
57
63
7000-8000 (2134-2438 m)
58
64
8000-9000 (2438-2743 m)
59
65
9000-10000 (2743-3048 m)
60
67
H18.2A
This series furnace is manufactured as a natural gas appliance that may be converted to LP gas through use of
the
Conversion Kit part number W370-0018
. This kit contains the conversion kit instructions, ori
fi
ces needed
for all models, the regulator spring for the gas valve, and a label to af
fi
x adjacent to the appliance rating plate to
alert subsequent service technicians of the conversion.
The parts removed for this conversion must remain
with the furnace for any future conversion back to natural gas.
H18.3
Refer to Conversion NG to LP Kit (W370-0018) for complete instruction.
WHITE-RODGERS 36J24-214 / 36J24-218P1 SINGLE STAGE GAS VALVE
1. Turn off the gas and electrical supply to the furnace.
2. Back off inlet pressure test screw (inlet pressure boss, see FIGURE 28 & 29) counterclockwise out one
turn maximum, with a 3/32” Allen wrench. Attach a hose and calibrated U-tube or digital manometer to the
inlet pressure boss. Hose should overlap boss 3/8”. The manometer must have a scale range of at least 0”
to 15” of water column.
3. Turn ON the gas and electrical supply and operate the furnace and all other gas consuming appliances on
the same gas supply line. Using a leak detection solution, check for leaks around the gas valve/manifold
connection and the burner ori
fi
ces. Repair any leaks before continuing.
4. Measure furnace gas inlet pressure with burners
fi
ring. Inlet pressure must be within the range speci
fi
ed on
the furnace rating plate. 5-7” w.c. (Natural Gas) or 11-13” w.c. (LP).
If the inlet pressure differs from the rating plate, check the gas piping size and/or consult with local gas
utility. If working on a natural gas system, contact the gas utility. They may insist on any service regulator
adjustments being made by their own staff.
13.2 NATURAL TO LP GAS
13.3 CONVERSION STEPS
13.4 CHECKING THE INLET GAS PRESSURE
Summary of Contents for Continental C95 - B SERIES
Page 27: ...W415 1245 B 03 19 15 27 IOM FIGURE 14A DIRECT VENT TERMINAL CLEARANCES...
Page 28: ...W415 1245 B 03 19 15 28 IOM IOM FIGURE 14B NON DIRECT VENT TERMINAL CLEARANCES...
Page 58: ...W415 1245 B 03 19 15 58 IOM IOM 23 0 SERVICE HISTORY 43 1...
Page 74: ...6 0 NOTES 44 1 W415 1245 B 03 19 15 UM 74...