Wohler RMQ-170-3G User Manual Download Page 5

821081: RMQ-230 Series User Guide

© 2012 Wohler Technologies, Inc. All rights reserved.

3

 

RMQ-230 Series

Installation Recommendations

Safety Symbols

Installation Recommendations

Heat Dissipation

The ambient temperature around the unit should not exceed 40

°

 

Celsius (104

°

 Fahrenheit). Allow plenty of space around the unit for air 

circulation.

Mounting/Bracing

Stands for desktop mounting are provided. The fixed desktop stand 

resists tipping over. The adjustable stand may need bracing when 

raised to its higher positions.

Wall mounting kits (not provided) are available for semi-permanent 

installations. Ensure that the lock hardware will resist movement from 

mobile vehicles or seismic vibrations.

Connections and Cable Recommendations

We recommend that you limit the length of the cables that you use for 

feeding HD-SDI signals sources to the HD-SDI inputs of the RMQ 

Series units and that you use a Belden 1694A cable (or equivalent). The 

HD-SDI inputs (

IN1

 and 

IN4

) can be up to 150 meters (492 feet) in 

length for 1.5 Gbps (HD), more for 270 Mbps (SD) and less for 3Gbps. 

WARNING: 

The symbol to the left warns of electric shock hazard inside the unit. 
Disconnect the power cord before removing access panels when 
installing upgrades. Only qualified service personnel are to operate the 
equipment with covers removed, and are to exercise caution to avoid 
personal injury.

Summary of Contents for RMQ-170-3G

Page 1: ...RMQ 230 Series RMQ 230 3G RMQ 230 HD RMQ 230 SD RMQ 230 A Quad Split LCD Multi Viewer Audio Video Monitors User Guide Part Number 821081 Revision C...

Page 2: ...r com Disclaimers Even though Wohler Technologies Inc has tested its equipment and software and reviewed the documentation Wohler Technologies Inc makes no warranty or representation either express or...

Page 3: ...ure adjustment to achieve the best possible image display The RMQ 230 Series supports 4 channel 3G HD SD SDI CVBS signal and a single HDMI signal input They can simultaneously display four signal inpu...

Page 4: ...only the attachments accessories specified by the manufacturer 8 Unplug the equipment during lightning storms or when unused for long periods of time 9 Use of a cart is neither recommended nor approve...

Page 5: ...nt installations Ensure that the lock hardware will resist movement from mobile vehicles or seismic vibrations Connections and Cable Recommendations We recommend that you limit the length of the cable...

Page 6: ...DC 4 7 A external power adapter and connects an A C mains power source 65W 100 to 240 VAC 50 60Hz through the IEC connector provided on the power adapter When the mains plug or appliance coupler is us...

Page 7: ...M Warranty card Mounting The RMQ 230 Series monitor comes standard with two table top stands one fixed and one adjustable Alternatively you can order the rack mount kit separately Refer to Figure 1 1...

Page 8: ...e following features 178 viewing angle Multi format analog and digital audio signals Four of 5 input signals 4 x SDI CVBS 1 x HDMI Adjustment of the parameters for each channel High quality waveform o...

Page 9: ...is defined in the OSD CONFIG FORMAT DISPLAY menu Level Meters Displays up to 16 channels 8 on the left and 8 on the right Define the meters setup in the AUDIO CONFIG AUDIO SOURCE and METER DISPLAY men...

Page 10: ...that channel s AUDIO CONFIG menu will follow the last selected video channel with these buttons The menus channel number also follows the last channel button pressed QUAD Pressing this button toggles...

Page 11: ...on again When the OSD Menu is not displayed you can press the ENTER button to quickly adjust the following parameters VOLUME Adjusts the volume from 0 to 30 BRIGHTNESS Adjusts the video brightness fro...

Page 12: ...10 RMQ 230 Series Rear Panel Features Figure 1 4 RMQ 230 Waveform Vector Display Rear Panel Features The descriptions of the rear panel connectors refer to Figure 1 5 below and Figure 1 6 and Figure...

Page 13: ...ower plug from an adapter Power Rocker Switch Toggles power to the monitor on or off RS485 Ports 2 RJ 45 Input and output connectors for external control Refer to Figure 1 7 and Table 1 1 on page 11 f...

Page 14: ...eard from the speakers headphones Figure 1 8 RMQ 230 Rear Panel Right SDI CVBS Video Inputs 4 BNC and SDI Outputs 4 BNC Only SDI video buffered from SDI inputs is output No analog to digital or digita...

Page 15: ...enu The submenus are STATUS Read only CH indicates the channel being configured COLOR TEMP MARKER AUDIO CONFIG USER CONFIG OSD CONFIG 1 Page 1 IMD DISPLAY 2 Page 2 IMD PROTOCOL 4 Use the Up or Down bu...

Page 16: ...e The values vary depending on input signal type and configuration settings COLOR TEMP ASPECT MODE SCAN MODE IP ADDRESS SUBNET MASK SERIAL NO MODEL Important To modify the options in the COLOR TEMP me...

Page 17: ...3 Color Temp Menu Continued Parameters Default Value Domain Range Important MARKER is disabled when SCAN mode is NATIVE or when the input signal is DVI or VGA Table 1 4 Marker Menu Parameters Default...

Page 18: ...the aspect function is assigned and scan control where OFF 80 85 88 90 93 95 MARKER LEVEL 1 Sets the luminance white level or brightness to display safety center and area marker line where 1 100 2 75...

Page 19: ...arameters Default Value Domain Range AUDIO SRC NONE Used to select the audio source type where OFF Disables audio source EXT Analog audio Inputs CH1 to CH4 selected EBD Embed audio only for SDI inputs...

Page 20: ...18DB OVER LEVEL 10DB Select the overload level 10DB 8DB 6DB 4DB 2DB Table 1 5 Audio Config Menu Continued Parameters Default Value Domain Range Table 1 6 User Config Menu Parameters Default Value Doma...

Page 21: ...bles display ASPECT MODE Toggles between 4 3 and 16 9 scaling to match input H V DELAY UNDEF none F2 BUTTON AUD METER LAYOUT 2 MODE 16 9 Select the aspect ratio when the display has one big with three...

Page 22: ...splays OFF Does not display IMD COLOR white Select the color in which to display the IMD text RED GREEN YELLOW WHITE IMD CHARACTER WOHler The IMD text can contain up to 16 characters including all let...

Page 23: ...Menu FORMAT DISPLAY off Select to display the video information OFF AUTO ON This following feature is not currently available CC off Select to display closed captions for CVBS signals only OFF CC1 CC...

Page 24: ...Domain Range IMD PROTOCOL Local Select the IMD protocol you want to use LOCAL UDP TSL3 1 TSL4 0 IMAGE VIDEO IMD ID 0 Select the IMD ID 0 through 255 IMD NAME S N N A The IMD serial number contains up...

Page 25: ...lly mode T1 T2 T1T2 T2T1 T1 T2 T1T2 T2T1 TLY SOURCE Standard Select the LED tally source For more information about the tally DB 9 switch closure refer to the information about the rear panel in Figur...

Page 26: ...including the fixed table stand 365mm H x 555mm W x 159mm D Shipping Weight 16 lbs 7 26 kg LCD Dimension 23 Aspect Ratio 4 3 16 9 native Resolution 1920 H x 1080 V Color Depth 16 7M 24 bit Viewing Ang...

Page 27: ...59 94 50 720p 60 59 94 50 1035i 60 59 94 480i 60 59 94 576i 50 PAL NTSC HD SDI 1080i 60 59 94 50 720p 60 59 94 50 1035i 60 59 94 480i 60 59 94 576i 50 PAL NTSC SD SDI 480i 60 59 94 576i 50 PAL NTSC An...

Page 28: ...0 Series monitors Table 1 13 RMQ 230 SDI Specifications Specification RMQ 230 Values Signal Compliance SMPTE 424M 425M A SMPTE 292M SMPTE 259M SMPTE 297M audio Connector BNC per IEC 169 8 Impedance 75...

Page 29: ...Diagram L R HDMI In Audio In 1 Tally Interface RS 485 IN OSD UMD Audio In 2 CH 1 In SDI Out 2 2 2 LCD 23 16 9 w OSD LED Tally Stereo Amplifier L R Audio In 3 Audio In 4 2 2 Audio Out 2 RS 485 OUT CH 2...