© 2010 Wohler Technologies, Inc. All rights reserved.
24
AMP V Series User Guide
Technical Functional Overview
at the time of order or requested from Wohler for application to
existing units.
Figure 1–16
Phase Correlation Labels
Positive amounts of correlation are indicated by an ascending amber
bar in the right channel bar graph; negative correlation is shown when
a red bar ascends in the left channel bar graph. While the audio level in
both channels is high enough, the phase correlation indication occupies
the bottom 13 segments of both bar graphs of a 30-segment stereo pair.
One additional segment above the active correlation region is always
off, to serve as a marker. The correlation display is visible only so long
as the VU audio level is above this blank segment (fourteenth segment
up on the 30-segment bar graph).
Technical Functional Overview
Figure 1–17 on page 25
through
Figure 1–19 on page 27
illustrate the
overall functionality of each of the AMP V Series monitors.