Page
15
Figure 2-6: Analog DB-25F Input and Output Connections
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
G
G
G
G
G
G
G
G
N/C
L
R
L
R
L
R
L
R
Pair 1
Pair 2
Pair 3
Pair 4
16.
AoIP SFP Module Cage
(optional): This provides a location in which to
insert the AoIP Module supplied with the OPT-DANTE (iVAM) and OPT
RAVENNA 64 options.
17.
Primary / Secondary 1GB ENET
(optional): Primary and Secondary
Gigabit Ethernet interfaces are provided with the AoIP option module.
SFP-2022-6 / SFP-2110 Address Setup
While the optional SFP-2022-6 and SFP-2110 modules monitor program audio
created from distinctly different technologies, both are connected to the network in
the same way and have the same requirements for addressing. Figure 2-7
illustrates the network connections they need.
Figure 2-7: SFP-2022-6 and SFP2110 Network Diagram
Ethernet Network & Switch
Broadcast Equipment
Throughout the Facility
iVAM-1 with SFP-2022-6 / SFP-2110
PC
Fiber
Optic
192.168.39.217
192.168.39.215
The optional SFP-2022-6 or SFP-2110 module furnished by Wohler Technologies is
manufactured by Embrionix and comes from the factory with a default IP address.
To integrate it into your digital network, you need to set its address to the source to
be monitored. You must use the emSET configuration software to set up this option.