Page
16
It is available from Wohler Technologies Technical Service. The procedure to
accomplish this is described in the
SFP-2022-6 / SFP-2110 Setup Guide
(part
number 821822), which is available at
ftp://ftp.wohler.com/Download-from-
Wohler/DoNotDelete/Emset
Channel Meters and Touch Operations
The audio mixer terminology of “solo” is used in this manual when referring to
muting all but a specific audio channel or pair.
Audio meters are displayed on touchscreen LCD display(s) in up to 8 channel pairs,
as shown in Figure 2-8.
Figure 2-8: Audio Level Meter Screens
-00
-60
-40
-30
-20
-20
-30
-40
-60
-00
S
t
u
d
i
o
A
5
6
3
4
1
2
-00
-60
-40
-30
-20
-20
-30
-40
-60
-00
S
t
e
r
e
o
A
S
t
u
d
i
o
B
16
15
14
13
10
9
S
t
e
r
e
o
B
12
11
Channel Identifiers
Channel / Cluster / Loudness Touch Selection Area
8
7
SDI-1
Loudness Reading
Loudness Cluster Marker
LKFS-M : -20.5
1.
Channel Identifiers
: Above the level meters are the Channel Identifiers.
They indicate the consecutive channel numbers in the selected source.
An arrow pointing to the left indicates that this is a left channel and
will be monitored in the left speaker.
An arrow pointing to the right indicates that this is a left channel and
will be monitored in the right speaker.
A square indicates that this is a center channel and will be monitored
in both speakers.
The symbol shown on channels 7 and 8 in Figure 2-8 indicates
that this channel pair is a Dolby bitstream. Refer to the Dolby
Zoom section of this chapter.
2.
Loudness Cluster Marker
: This orange bracket marks which cluster is
currently being measured for Loudness.
1
2
3
8
7