c) Reservoir 07
Screw off the cover of the tank
Fill in new oil into the tank
Screw on the cover of the tank
6.5.2 Venting of the cartridge reservoir
(only cartridge 40)
As for bleeding the cartridge / container, loosen the bleeding plug screw and wait until the
medium emerges without bubbles from the bleeding bore.
6.5.3 Venting of the unit
Vent both the line and unit to get the unit working satisfactorily. For that purpose, actuate the
drive assembly as many times as necessary to have the lubricant emerging at the outlet
without air bubbles.
Ventilation screw