6.  Transport, installation, start-up and putting out of operation 

6.1  Transport 

 
Transport the unit cautiously to its destination. For that purpose, make use of proper  
equipment.  

6.2  Unpacking

 

 

Lift the unit carefully from the packaging and place the unit on a stable as well as plane  
support. 
 

 

 
Note! 

Consider that inside the unit and attached components according to 
the bill of delivery there might be residues of blue-coloured test oil. 

 

 

6.3  Installation 

 

The unit is prepared for being mounted on wall by means of two screws M6. The mounting 
area has to be that stable to absorb the weight of the unit including the filled cartridge. 

In 

addition, make sure that the mounting surface is vertical and plane. 

 
 Drilling pattern for wall mounting: 
 
 
 
 
 
 
 
 
 
 
 
 
Fixing for screws M8 or 
wall mounting screws M6 

Summary of Contents for GMV-C

Page 1: ...Operating manual Page 1 of 32 B0825 GMV C Piston pump GMV C Translation of the original operation manual Version EN 12 2018...

Page 2: ...ng manual do no coincide with the original ones then the original operating manual German is to be referred to for clarification or the manufacturer to be contacted Copyright This document shall neith...

Page 3: ...to design 9 3 5 Technical data 10 3 5 1 Components 10 3 5 2 Dimensions 10 3 5 3 Technical data 13 3 5 4 Level monitoring 14 4 Description of function 15 4 1 Drive 15 4 2 Working mode GMV C 15 4 3 Lev...

Page 4: ...ration 25 7 Operating manual 25 7 1 Trouble shooting fault eradication 25 7 2 Replacing the lubricant cartridge 26 7 3 Switching off 26 8 Cleaning servicing fault remedy and repair 26 8 1 Cleaning 26...

Page 5: ...ied users who have been instructed or trained for the operation of this product 1 2 Obligation to read As owner and user of this unit you are obliged reading and understanding this operating manual in...

Page 6: ...warning words used in safety instructions safety rules and references of this operating manual do mean Danger Immediately threatening danger that may lead to heavy body injuries Warning Possibly dange...

Page 7: ...ation plate has been attached to the side of the pump case and informs on Manufacturer Type GMV C No order number for example 612345 1 Year of production 2 4 Manufacturer and address Eugen Woerner Gmb...

Page 8: ...n of the unit is determined by the medium to be supplied Therefore to finally define the range of application consult also the technical data sheets of the medium to be used 3 3 Environmental conditio...

Page 9: ...ance and service instructions in this operating manual Any other usage or any usage beyond the designed one may lead to heavy personal and material damages The delivery of gases liquefied gases gases...

Page 10: ...cal data 3 5 1 Components The unit consists of maximum 3 components which may vary according to the real executions Pump case Drivey Reservoir and level monitoring 3 5 2 Dimensions 1 Outlets 2 3 2 way...

Page 11: ...erating manual Page 11 of 32 B0825 GMV C Reservoir Reservoir 04 Equipment for cartridges 400 g System Lube Shuttle Reservoir 05 Equipment for cartridges 500 g System Reiner Reservoir 0 connection G 1...

Page 12: ...Operating manual Page 12 of 32 B0825 GMV C Reservoir 40 for grease cartridges 400 g acc to DIN 1284 Reservoir 07 for mineral oil...

Page 13: ...m Grease up to NLGI class 2 Mineral oil Temperature range 10 50 C Reservoir Cartridge 400 g acc to DIN 1284 Cartridge 400 g System Lube Shuttle Cartridge 500 g System Reiner Oil reservoir 0 7 l Air pr...

Page 14: ...eservoir 04 05 Reservoir 40 Reservoir 07 2 1 3 5 4 Level monitoring Reservoir 04 05 Voltage 10 30 VUC Amperage max 0 5 A Protection class DIN EN 60529 IP67 Plug M8x1 3 pin Switching function NO contac...

Page 15: ...e supply For that purpose an external control is required 4 2 Working mode GMV C The piston pump consists of the pump case with supply piston pneumatic drive unit including 3 2 directional control val...

Page 16: ...ing level control is connected by a plug M8x1 3 pin The distance between filling level control and base plate has to amount to minimum 20 mm Increasing the distance the residual quantity between empty...

Page 17: ...g connection M8x1 3 pin 5 Safety instructions 5 1 Fundamental The unit is shipped from the works in faultless condition and guarantees high technical safety The unit complies with the rules of technol...

Page 18: ...d persons from access to the unit Keep foreign persons away from dangerous areas and dangerous sites Inform repeatedly present foreign persons on residual dangers As for residual dangers see section R...

Page 19: ...age of working equipment Operate the unit in clean and faultless state only Never remove modify bridge or neglect any protection safety and monitoring equipment in no case Do not reconstruct or change...

Page 20: ...l as plane support Note Consider that inside the unit and attached components according to the bill of delivery there might be residues of blue coloured test oil 6 3 Installation The unit is prepared...

Page 21: ...DIN VDE 1000 10 Connect the unit to the voltage supply and control Before starting up double check the installation for correct electrical connection Warning There is danger to life when intervening i...

Page 22: ...i clockwise from the bars Remove the cover slowly to top Caution While opening the cover secure the area between cover and cartridge by hand to hinder the spring from bouncing out in order to prevent...

Page 23: ...to hinder the spring from bouncing out to prevent damage and injury b Cartridge 40 Replacement of the cartridge Unscrew reservoir and pull back piston bar up to stop Then insert both sides opened grea...

Page 24: ...tridge 40 As for bleeding the cartridge container loosen the bleeding plug screw and wait until the medium emerges without bubbles from the bleeding bore 6 5 3 Venting of the unit Vent both the line a...

Page 25: ...bricant supply Pneumatic cylinder does not work Check the pneumatic connection Check the electrical connections of the 3 2 way valve Check the fuse Check the 3 2 way valve Cartridge reservoir is empty...

Page 26: ...onnect the unit from the power supply and lock the unit from re switching on Important While working on the unit and even during your absence ensure that no other person can change or create another s...

Page 27: ...tant Consider also the maintenances instructions in the operating manuals of the single components in the annex 8 3 Inspection chart No Description Interval 1 Inspect if the safety equipment has been...

Page 28: ...ation Order no Usable for Illustration Cable socket 3 pin M8x1 length 2 m 979 046 38 Level monitoring and function control F Cable socket 3 pin M12x1 length 5 m 913 404 19 Level monitoring F reservoir...

Page 29: ...stimating the damage and repair expenditure of the goods without delay and in economical manner we need in addition the precise description of the complaint and conditions of use Quotations are drawn...

Page 30: ...ained and cleaned 2 the remaining residual contaminations are free of health and environment hazardous substances 3 the substances used in the product s correspond to the instructions in the product d...

Page 31: ...ation of harmlessness Herewith we declare that the product GMV C from year of production 2015 fulfils all relevant provisions of the directive Machinery 2006 42 EC In addition the machine complies wit...

Page 32: ...Operating manual Page 32 of 32 B0825 GMV C 11 2 Declaration of Conformity...

Reviews: