Operating manual
Page 13 of 32
B0102
GMI / GML / SAB / GOI
Build-in level switch: (GMI / SAB / GOI)
3.5.3 Technical data
In its basic version, the unit comprises the pump body with magnet exciter and a reservoir
mounted on. The technical data of this unit is as follows:
Unit:
GMI-A
GML-A
SAB-C
GOI-A
Delivery volume per
stroke and outlet
30 mm³
30 mm³
15 mm³
15 mm³
Number of strokes
at max.
approx.
100 min
-1
approx.
250 min
-1
approx.
250 min
-1
Number of outlets
1 … 4
1
… 4
1
… 4
1 or 2
Actuation time at
min.
approx. 0,1 s
approx. 0,1 s
approx. 0,1 s
approx. 0,1 s
Medium
Oil
11
… 1900 cP
Grease
up to NLGI-Kl. 2
Oil
11
… 1900 cP
Oil
11
… 1900 cP
Temperature range
-10
… +50 °C
-10
… + 50 °C
-10
… +50 °C
-10
… +50 °C
Reservoir capacity
0,7 l
Cartridge 400 g
DIN 1284
0,7 l
0,7 l
Air pressure at max
-
-
-
6 bar
Material
pump body
Aluminium
Aluminium
Aluminium
Aluminium
Material reservoir
Polyethylene
Steel
Polyethylene
Polyethylene
Material
gaskets
FPM
FPM
FPM
FPM