background image

 

 

www.wobit.com.pl 

Manual  -SIC184 – 27.10.2014 – v.1.1 

   page 11 

 

For driver power supply it is recommended to use a non-stabilized power supply with output voltage 
in range +12..+36V. The power supply must receive return energy of the motor, which is provided by 
output capacitors with capacity bigger than 4700µF. 

A minimal current efficiency of power supply should be match according to formula below: 

Izas= 12/Uzas*Ister  

Where: 

Izas

-a minimal current efficiency of power supply, 

Uzas

 – voltage supply, 

Ister

- set driver 

current.  

Exemplary values of minimal current efficiency used power supply : 

Motor current [A] 
Power supply[V] 

12 

1A 

2A 

3A 

4A 

24 

0,5A 

1A 

2A 

3A 

36 

0,4A 

0,8A 

1,5A 

2,5A 

  

 

Warning! 
Opposite polarity or exceeding of max voltage supply can cause damage of 
the driver.  
To  small  output  capacitors  or  none  capacitors  can  damage  the  driver  or 
cause incorrect operation, while operation of the driver with high voltage 
and  a  big  motor,  which  operates  dynamic  (sudden  decreasing  velocity  of 
the motor).  
It  is  recommended  to  use  electrolytic  capacitors  1000µF  at  max  driver 
currents and max rotational velocity (>2 rps).  

 

2.5 Stepper motor  

Motor should be connect to the driver by 4-pin cable. To reduce noise it is recommended to use 
twisted cable (A with /A, B with /B), preferably shielded. In case of unipolar motors (with 6 or 8 
derivation cables) you should connect them according to examples below. 

Summary of Contents for SIC184

Page 1: ...P P H WObit E K J Ober s c 62 045 Pniewy Dęborzyce 16 tel 48 61 22 27 410 fax 48 61 22 27 439 e mail wobit wobit com pl www wobit com pl SIC184 Manual Stepper motor servo controller ...

Page 2: ...otor 11 2 6 RS485 connector 12 2 6 1 Driver communication in Modbus RTU protocol 13 2 6 2 Communication between SIC184 drives at internal protocol 13 2 6 2 Communication between SIC184 controllers in internal protocol 14 2 7 USB connector 15 2 8 Transistor outputs 16 2 9 Inputs 16 2 10 Encoder 17 3 Configuration and description of controlling SIC184 18 3 1 Exemplary connection of the driver 18 3 2...

Page 3: ...nual Prior to first start up of the device please make sure all cables are correctly connected Provide appropriate working conditions in compliance with the device specifications e g power supply voltage temperature maximum current consumption Before making any modifications to wiring connections disconnect the power supply voltage 1 2 Assembly recommendation In environments with unknown noise lev...

Page 4: ...per motor position Except start stop inputs SIC 184 device has also 2 universal inputs 2 outputs and dedicated inputs based motor position It allows completely eliminate PLC driver in some applications 2 1 1 SIC184 driver as simple and cost effective solution at controlling of stepper motor SIC 184 Stepper motor servo controller allows to replace PLC controller and a stepper motor driver in range ...

Page 5: ...C184 driver independent and synchronous operation of up to 16 motors simultaneously SIC184 controllers can cooperate depending on each other in multi master and master slave modes depends on programming way On account to that there is a possibility of interdependent operation up to 16 modules simultaneously which enables complex interdependent motion trajectories Controllers communicate to each ot...

Page 6: ...ity of independent addressing in range 1 16 provides simultaneous controlling of up to 16 stepper motors from devices such PLC drivers HMI panels or other master Modbus RTU devices 2 1 4 SIC184 driver indexer for high current stepper motor driver SIC184 driver has additional output for external power driver of stepper motor in STEP DIVISION standard which allows for controlling of motors with high...

Page 7: ...rolling input output signals online operation of the driver etc and direct generate of motion command position velocity This software enables also programming the driver by motion command created in ML PROG environment ML PROG software creating of motion programs and possibility of simultaneous programming up to 16 drivers by RS485 interface SIC184 drives operate at common RS485 bus can be program...

Page 8: ...er possibility of programming up to 300 motion command Possibility of cooperation with any incremental encoder 2 universal inputs 3 24V and 2 transistor outputs 1A 30VDC USB interface for configuration programming and diagnosing of controller intuitive configurable software SIC184 CONFIGURATOR RS485 MODBIS RTU interface for communication between controllers or controlling form MASTER controller e ...

Page 9: ...ignaling diodes Signaling of driver power supply Turn off blinking error overvoltage of the driver Turn on driver is ready for operation Blinking RS485 communication Turned off the program is stopped Blinking the program is withhold Turned on the program is started D1 D2 D3 D4 are turned on while the driver is actualizing the software ...

Page 10: ...e while signal must be given on particular input to activate it 10 START input starting the program 11 STOP input stopping the program 12 IN1 universal input 1 13 IN2 universal input 2 14 HOME1 homing input 1 15 HOME2 homing input 2 16 COM common signal for inputs 17 GND ground Encoder Maximal current consumption of encoder 5V power supply clamp can reach 300mA For encoders supplied by 12 24 VDC v...

Page 11: ...ent A Power supply V 1 2 3 4 12 1A 2A 3A 4A 24 0 5A 1A 2A 3A 36 0 4A 0 8A 1 5A 2 5A Warning Opposite polarity or exceeding of max voltage supply can cause damage of the driver To small output capacitors or none capacitors can damage the driver or cause incorrect operation while operation of the driver with high voltage and a big motor which operates dynamic sudden decreasing velocity of the motor ...

Page 12: ... converter and ML PRG software Communication between SIC184 divers while synchronic operation Controlling from external device by Modbus RTU protocol Default transmission parameters Baud rate 38400 bps bits 8 stop bit 1 parity none Modbus address 1 for Modbus RTU communication Internal address 0 for communication and programming by ML PROG Transmission parameters can be configured by SIC184 KONFIG...

Page 13: ...s and configuration of baud rate chapter Configuration of Modbus RTU interface It is possible to address up to 16 drivers addresses 1 16 Picture 2 Example of motors controlling by Modbus RTU Protocol 2 6 2 Communication between SIC184 drives at internal protocol SIC184 driver can communicate through its own protocol by RS485 This protocol allows for programming one and or many drivers on common RS...

Page 14: ...ion between SIC184 controllers in internal protocol SIC184 driver can communicate by its internal protocol through RS485 This protocol allows programming of one and or many drivers on common RS485 bus by ML PROG software as well as communication between drivers while earlier recorded motion program By sending proper commands from one driver to another you can accomplish master slave controlling on...

Page 15: ...les by RS485 2 7 USB connector USB connector is used for communication between driver and SIC KONFIGURATOR software After connecting driver to PC you don t have to install drivers Detailed description of SIC KONFIGURATOR software is located at Driver configuration by SIC KONFUGURATOR chapter ...

Page 16: ... below On clamp no 6 is available voltage supply of the driver which can be used for activation of external circuits Picture 4 Internal construction and way of connection external devices to transistor outputs 2 9 Inputs The device has 6 opt insulated inputs Start and Stop inputs for activation and deactivation of the program Home1 and Home2 inputs for determine of edge motion position and based p...

Page 17: ...al encoder mounted indirectly e g with gearbox of stepper motor Magnetic linear sensor mounted on executed element powered by stepper motor Encoder which cooperate with stepper motor provides better control of motor position and protects against loosing of position steps by motor in case of its overvoltage or unexpected stop Max frequency of encoder input 50kHz Encoder resolution from 16 4 bit up ...

Page 18: ...and for control of correct the connection is designed tab Encoder In SIC184 KONFIGURATOR software chapter encoder settings 3 Configuration and description of controlling SIC184 3 1 Exemplary connection of the driver Picture 9 Exemplary scheme of connection external devices Detailed description and way of connection particular external elements is described in chapters Power supply Stepper motor RS...

Page 19: ...and position can be set with fraction values Picture 10 Motor motion parameters Exemplary for motion parameters Vmin 0 01 Vmax 1 Amax 1 and set position 10 revolutions motor will speed up to 1rps velocity at 1 sec time will made next 8 revolutions then will slow down to 0rps velocity at 1 sec 3 3 Driver configuration by SIC184 KONFIGURATOR program For configuration of SIC184 drives is designed SIC...

Page 20: ...am Executive system Windows XP Windows Vista Windows 7 32 bit 64 bit software actualization only for 32 bit version Processor 1 GHz RAM memory 256 Mb 3 3 1 Setting of step division and motor current SIC184 KONFIGURATOR Tab Default settings Motor current should be set in dependence on used stepper motor Setting to high current for weaker motor cause its quicker heating or damage Automatic current r...

Page 21: ...on number of pulses per revolution To correct correctness of encoder connection to controller you should use test function test button If encoder is connected with motor indirectly e g through gearbox or its resolution is unknown you also can use test function This function makes full motor revolution and reads out number of pulses generated by encoder which then should be written to encoder resol...

Page 22: ...n counter Since this time set position number of revolution made by motor will be related to this position In the driver there are motion commands used for homing This commands can be given by Modbus RTU or executed motion program inside the controller GoHome command Homing can be called from SIC184 KONFIGURATOR program Configuration of Homing mode SIC184 KONFIGURATOR Encoder and Homing tab The dr...

Page 23: ...g and setting velocity position for motor motion with default parameters or set in Motion parameter box 3 3 6 Configuration of RS485 Modbus RTU interface SIC184 KONFIGURATOR RS485 tab Baudrate 9600 19200 38400 57600 115200 bps allows to define baudrate of RS485 Device address MODBUS 1 16 allows to define SIC184 address on Modbus RTU bus Preview of Modbus RTU transmission allows to preview Modbus f...

Page 24: ...ws opening of mpl file with motion script generated in ML PROG program Module number This command allows to select proper motion program from script ML PROG program allows for creating programs for 16 drivers simultaneously and records it in one script Send to SIC184 sends earlier readied out program to driver Program is recorded in non violate memory of the driver Receive from SIC184 enable read ...

Page 25: ...1 8 step 24 rps 1 10 step 22 rps 1 16 step 19 rps 1 20 step 9 rps 1 32 step 6 rps 1 40 step 5 rps 1 64 step 3 rps Trajectory generator Control of position velocity and acceleration CLK DIR EN output signals for external power driver Low state 0V high state 5V Max frequency 38 kHz pulse width 20us Encoder Input A B signals low state 0V high state 3 24V Max input frequency 50 kHz Resolution from 16 ...

Reviews: