50
When pressed, button
9
lights up until the set quantity has
been dispensed. In order to cancel a selection prematurely,
turn selector
5
to “0”. However, the brewing process in
progress will be completes first.
Dispensing coffee via the free-flow spout
Selector
5
must be set to
(free-flow spout) so that
coffee can dispensed via the flexible hose
19
into a waiting
storage urn.
Fig. 2
Example: Free-flow coffee has been programmed and the
selector set to 5 litres.
The amount of coffee to be brewed is set on a scale
extending up to 100 litres. The brewing process is started
via the buttons (NORMAL) and (SPECIAL). The selected
button
9
lights up until the set amount of coffee has been
brewed.
Fig. 3
Example: NORMAL lights up until 20 litres have been
brewed.
The small LED between the buttons NORMAL and
SPECIAL always lights up and indicates that only coffee is
being dispensed via the flexible hose
19
(See Chapter
Via
the free-flow spout
on page
53
).
The WMF PROGRAMAT GV also includes
an automatic
brewing function
in combination with the WMF storage
urns (type 03.6620.0001 and 03.6620.1001). The control
line
20
is plugged into the storage urn and the WMF
PROGRAMAT GV for this purpose:
Fig. 4
If the quantity selected exceeds the capacity of the storage
urn (20 litres), the machine automatically continues to brew
coffee until the programmed quantity has been brewed. The
signal for renewed brewing is output to the coffee machine
whenever the level in the storage urn drops below 15 litres.
20