30
5.1 Ignition failure
Green LED "Button" (5), "Standard" (3) or "Start-Stop" (4) blinks 2x
This signal appears and indicates a malfunction if the flame fails to ignite after 7 seconds.
In case of ignition failure check the burner head
(7)
for possible clogging, check the
correct input pressure of the gas supply and verify that the correct nozzle is installed.
In case of this malfunction the gas valve of the burner will be shut off automatically.
Nozzle
N
: natural gas, 18 - 25 mbar
Nozzle
P, B
: propane / butane gas, 47.5 - 57.5 mbar
5.2 Flame failure
Green LED "Button" (5), "Standard" (3) or "Start-Stop" (4) blinks 3x
This signal indicates a malfunction if the flame is extinguished by external factors
and fails to reignite within 5 sec. In case of flame failure check the burner head
(7)
for possible clogging and verify the correct input pressure of the gas supply.
In case of this malfunction the gas valve of the burner will be shut off automatically.
5.3 Overtemperature
Green LED "Button" (5), "Standard" (3) or "Start-Stop" (4) blinks 4x
This signal indicates a malfunction if the interior temperature has exceeded 70 °C. At
a normal room temperature with normal air circulation the unit is suited for continuous
operation. In case of overtemperature increase the air ventilation or change the
operation site. In case of this malfunction the gas valve of the burner will be shut off
automatically.
5.4 Burner head assembly monitor
Green LED "Button" (5), "Standard" (3) or "Start-Stop" (4) blinks 5x
This message indicates that the burner head is removed. Further operation is possible
after the burner head is reinstalled.
5.5 Burner Head Control (BHC)
Orange LED "Burner Head HOT / BHC" (6) flashes
This signal indicates that the time limit (30 seconds) is turned on in operating mode
"Start-Stop" and "Button" due to a clogged burner head. For cleaning the burner head
see paragraph 6.1
.
5.6 Foot pedal connection control
LED "Standard" and "Start-Stop" are blinking alternately
Tethered foot pedal is not connected with the burner. Plug in the foot pedal.
[Fuego basic RF] Wireless foot pedal out of range or signal interrupted.
Switch on wireless foot pedal or move within range
(see paragraph 2.3)
.
If necessary, re-programme the wireless foot pedal
(see paragraph 2.5)
.