29
3.2 Pedal Standard
The flame is ignited by operation of the foot pedal. The foot pedal remains depressed
for the duration of use. The flame is extinguished upon release of the pedal.
3.3 Pedal Start-Stop
The flame is ignited by operation of the foot pedal. The flame is extinguished after
renewed actuation of the foot pedal. Additionally the flame is automatically extinguished
when the burning timer has expired after 60 min. Alternatively the flame can be
extinguished by a short push on the function knob.
While no foot pedal is connected, only Button "Start-Stop" is available.
4. Safety symbols and safety functions
The safety LED's appear during usage to warn the user of potential hazards.
4.1 Residual heat display
The LED „Burner Head Hot / BHC“
(6)
indicates a hot burner head. As long as the
LED shines, DO NOT TOUCH the burner head. This can cause serious burns.
Even after switching-off the unit, the residual heat LED remains "on" till the burner head
is cooled down.
Disconnecting the power supply or removing the power cord will clear
the residual heat display even if the burner head is still hot.
4.2 Burner Head Control (BHC)
If the burner head is clogged, the amber LED "Burner Head HOT / BHC"
(6)
will flash
you have to clean the burner head
(see paragraph 6.1)
, otherwise the maximum
burning time in the operating mode "Button" and Pedal "Start-Stop" is limited to 30
seconds
(see paragraph 5.5)
. If burning times longer than 30 seconds are required
in case of a clogged burner head, the operating mode "Pedal Standard" can be used
without time limit.
4.3 Automatic unit switch off
The unit switches itself off automatically after 4 hours if the flame has not been lit in this
period. All indicated malfunctions are automatically switched off after 4 hours, too
(see paragraph 5)
. For further operation, switch the unit on again.
i
5. Error displays
If there is an error during operation, eventually the gas valve of the burner automatically
closed and different flashing LEDs indicate the error.
All error displays can be reset by a long push (> 2 seconds) on the function knob
(1)
. In case of overtemperature the unit needs to be cooled down and in case of
burner head assembly monitor, the burner head needs to be reinstalled before a
reset is possible.
!