background image

IR Intelligent Speed Dome Camera User Manual 

 

- 10 - 

c

Press “SHOT” key; 

d

Press “ACK” key; 

e

The dome camera will be moved to the left limit required by the position by shaking joystick. 

f

Enter“92” 

g

Press “SHOT” key; 

h

Press “ACK” key; 

2

Start    A

B scan 

By controlling keyboard or DVR to implement the command “set No.93 preset position”

If 

you not set the left/ right limit position, it will prompt to set the left/ right limit position

 

Example;Using a type of controlling keyboard to start using auto scanning 

a

Enter“93”; 

b

Press “SHOT” key; 

c

Press “ACK” key; 

3

Limit position on left and right to delete 

By controlling keyboard or DVR to implement the command “set No.94 preset position” 

Example:  using  some  items  of  controlling  keyboard  for  elimination  of  limit  position  on  left  and 

right 

a

Enter“94”; 

b

Press “SHOT” key; 

c

Press “ACK” key; 

4

360 º horizontal scan speed setting 

The  IR  dome  camera  has  5  level  was  adjustable  when  horizontal  rotation  speed  of  auto 

scanning.  operation  method  by  controlling  keyboard,  DVR  to  implement  “set  No.65  preset 

position, The scanning rotation speed is 3°/sec;“set No.69 preset position”

the scanning rotation 

speed  is  40°/sec;  360 º  Horizontal  rotation  speed  setting  commands  when  auto  scanning  please 

reference the below table. 

Horizontal rotation speed 

Setting commands 

Horizontal rotation speed 

Setting commands 

3°/sec 

Call 

NO.65 preset 

6°/sec 

Call 

NO.66 preset 

  9°/sec 

Call 

NO.67 preset 

15°/sec 

Call 

NO.68 preset 

40°/sec 

Call 

NO.69 preset 

 

 

Example:  Using  some  items  of  controlling  keyboard  to  set  horizontal  speed  rotation  be  9°/sec 

when scanning   

a

Ener“67” 

b

Press “SHOT” key; 

c

Press “ACK” key; 

5.4 Factory Default 

By  controlling  keyboard  or  DVR  to  implement  the  command  “call  No.96  preset  position” 

then  can  make  the  dome  camera  settings  back  to  factory  default  state.  Has  now  set  all  preset 

position function will be cleared (limit position on left and right will not be cleared)   

Example: Using a type of controlling keyboard to restore the factory default   

a

Enter “96”; 

b

Press “SHOT” key; 

c

Press “ACK” key; 

 

Summary of Contents for ON-AP6RK-33X-2M

Page 1: ...IR Intelligent Speed Dome Camera User Manual...

Page 2: ...installation Don t touch the dome cover directly by hand When connecting the power source please follow all electric safety standards and only use the power supply designed for this device Keep the v...

Page 3: ...etting and remove the setup of scanning speed 9 5 4 Factory Default 10 6 System OSD menu setup for models with OSD menu 11 6 1 Self Test Display 11 6 2 Main Menu 11 6 3 Syetem Information 12 6 4 Syste...

Page 4: ...ble that are damaged under normal use by judge of us at no additional charge Free services and repairs will not be covered under the following conditions 1 Unauthorized repair or disassembly of the pr...

Page 5: ...d make the irradiation Angle difference from the viewing Angle of current camera for the IR light producing periodic rest reduce the infrared lamp panel working current effectively control components...

Page 6: ...oard etc Preset 255 presets Patrol 4 groups 16 presets per group stay time for each preset positions 4 8 10 15 20 seconds adjustable Patter 4 groups 3 mins per pattern Scan one group frame scan one gr...

Page 7: ...d PTZ and camera lens control of dome camera This product designed the dial switch located on the sphere given the set of convenient and stability there is a piece of gusset plate under the ball cover...

Page 8: ...38 10101100 53 10010000 9 00011000 24 11100100 39 01101100 54 01010000 10 10011000 25 00010100 40 11101100 55 11010000 11 01011000 26 10010100 41 00011100 56 00110000 12 11011000 27 01010100 42 100111...

Page 9: ...to the angle in demand by pressing the key zoom b Enter 1 key c Press SHOT key d press and hold the smart key of the joystick e Press ON key 2 Call preset position Refer to the calling preset functio...

Page 10: ...r cruise route and the relation table of calling command Cruise route Call command Presets in cruise route NO 1 Call NO 71 preset 1 16 presets NO 2 Call NO 72 preset 17 32 presets NO 3 Call NO 73 pres...

Page 11: ...hen horizontal rotation speed of auto scanning operation method by controlling keyboard DVR to implement set No 65 preset position The scanning rotation speed is 3 sec set No 69 preset position the sc...

Page 12: ...em Information System Setup Function Setup Display Setup Camera Menu Setup Factory Default Exit System Information Version V5 0 4 Address 01 Protocol Pelco D Self test OK System Setup motion flip on S...

Page 13: ...1 version V5 0 4 2 address 01 3 protocol Pelco D 4 baud rate 2400 5 self test OK 6 back 6 4 System Setup Users can setup the speed dome function by this menu Move the cursor to system setup press righ...

Page 14: ...5 Return 6 5 2 Idle Func Through Idel func you can set the PTZ camera Idle task and Idle waiting time when the PTZ mil in the setting f time without any operation the PTZ camera will perform to autom...

Page 15: ...Trace func 1 Trace NO 01 2 Setting trace 3 Running trace 4 Clearing trace 5 Return 6 6 Display Information Through the Display information you can open and close the system time system position setti...

Page 16: ...Intelligent Speed Dome Camera User Manual 15 6 8 Restore The Factory Value Chose Restore the factory value you can drop all of the PTZ camera s parameter such as 6 9 EXIT Chose exit to exit the PTZ me...

Page 17: ...rd the third path call83 To record the fourth path call84 end of the recording track call85 Start the first track call86 Start the second track call87 Start the third track call88 Start the fourth tra...

Page 18: ...n and external force factors it can be called the NO 96 preset postion to make a factory default 6 In order to control the infrared light calorific value effectively and ordinary infrared machine flas...

Page 19: ...offer free repair but it will pay for the material cost when include any of below situation 1 It is damaged due to not follow the manual to operate 2 It is damaged due to lightning fire disaster and o...

Page 20: ...rod or other measures 5 Lightning protection of outdoor installation and wiring and grounding design must be combined with the building lightning protection requirements into consideration as well as...

Page 21: ...Eliminate Power shortage to the power supply Change Image is unstable Video cable is disturbed Eliminate Power shortage to the camera power supply Change the better power supply and best to put it nea...

Reviews: