24
Translation of the original operation manual Airless
Phoenix_BAoDB_en_1210
•
jw
Adjustment of the fog oiler on the air maintenance unit
➤
Let the air motor run slowly at an air inlet pressure of
approx.4 bar.
➤
Check the sight glass on the fog oiler to ensure that
one drop of release agent is fed into the compressed
air at every 10 - 15 double strokes of the air motor. If
this not the case, the adjusting screw on the fog oiler
has to be set accordingly.
➤
Check the oil level in the reservoir daily.
The air maintenance unit may not be operated
without oil. The maximum oil level is marked
with a line around the reservoir.
➤
To fill the reservoir, remove the filler screw or
remove the reservoir and fill directly.
➤
Only use the release agents and anti-freezing agent as
indicated in Chapter "Appendix/ Auxiliary materials".
Condensed water drain
➤
The collected condensation will be automatically drai-
ned by the drain valve. Place the hose into an empty
catch basin.
➤
Check the reservoirs regularly for contamination and
clean as necessary.
Notes to the oil reservoir/water cutoff
➤
To remove reservoir:
➤
Press release downwards.
➤
Turn reservoir counter-clockwise.
➤
Montage:
➤
Take care during assembly that the O-ring is seated
properly in the housing!
9 Maintenance