Operation
5.3 Decommissioning
Overview of the work sequence for decommissioning:
1.
Flush the unit completely (see chapter 5.3.1 on page 30)
2.
Shut down and depressurise the unit (see chapter 2.7.1 on page 16)
3.
Disassemble and clean the fluid pump (see chapter 5.3.2 on page 30)
4.
Assemble the fluid pump (see chapter 5.3.3 on page 32)
5.3.1
Complete flushing
If working with dual component materials, the pot life must be observed.
The unit must be flushed and completely cleaned with the appropriate sol
-
vent within the pot life given by the material manufacturer.
1.
Flush the pump at first through the drain hose, as described in chapter
5.2.4 on page 29 (work steps 1-16).
2.
Lock the spray gun and remove the nozzle.
3.
Clean the nozzle by hand.
4.
Hold the spray gun into the collecting vessel.
5.
Trigger the spray gun until clean flushing agent appears.
6.
Hold the spray gun into the flushing agent drum and allow the pump to
circulate flushing agent via the spray gun for 2-3 min.
7.
Exchange the flushing agent drum for a clean one with new flushing agent
and repeat the complete flushing procedure (via the drain hose and the
spray gun).
5.3.2
Disassembling and cleaning the fluid pump
WARNING
Despite releasing the pressure, material congestion or agglomeration of
material may mean that there are residual pressures still present. These may
suddenly release during disassembly work and can result in serious injuries.
➤
You must be particularly careful during disassembly work!
➤
When disconnecting material hoses you should cover the screw fitting
with a cloth to catch any escaping material sprays.
CAUTION
The parts of the fluid pump are heavy. At best, work In pairs and position a
soft mat to catch falling parts.