Keypad test  

We recommend a final keypad test using function menu 5 to ensure that all the numeric keys 
function properly. 
  

 

 



 

 

Checking the menu system

 

 

Press the keys in the 
sequence  





 

 

 

 

=

 

 

Press each numeric key once.  
A functional key is indicated by a 
double signal tone. 
A key that is not recognised is 
indicated by a long signal tone and 
the function test is terminated. The 
system must be checked.

 

 

 

 

 
 

 
 

 

 

 

System setup  

The  setting  options  and  the  control  sequences  that  are  required  are  described  in  the  user 
manual.  
 
We therefore recommend the following procedure: 

  Setup of the users [menu 1] 

  if applicable, parameterisation of the inputs and outputs [menu 6] 

  if applicable, setting up the Dualcode condition [menu 6] 

  if applicable, setting up the delay time [menu 9] 

 

 

 

In particular, the user system can be made markedly faster by using setup mode [menu 8]. 

The repetitive input of the master code is then restricted to selecting setup mode. 

 

 

Summary of Contents for Anchor 4000 Series

Page 1: ...neral 2 Preparation for installation 3 Installation dimensions 3 Preparation of the boltwork door 3 Installation 4 Wiring installation 5 Connection of an analog keypad 5 Connection P signal plus UART 6 Function test 6 Input of the opening code 6 Keypad test 7 System setup 7 Mount the keypad before installing the electronic lock All the keypads of the Primor series can be used Details on installing...

Page 2: ... the electronic lock in the area of the cutouts in the safe door It is essential that the lock is protected against attacks from outside We recommend that you protect against access the security relevant parts of the high security lock also when the door of the container that holds the valuables is open It is not permissible to use two locks of the same type in connection with analog keypads witho...

Page 3: ...on of the boltwork door For installation of the lock there must be three threaded holes with 5 mm screw in depth for attachment to the boltwork or within the safe door The electronic lock is to be attached with the supplied M6 or 1 4 screws or cylinder screws minimum strength class 8 8 The length of the screws must be 25 mm or more so that a minimum screw in depth of 5 mm is attained ...

Page 4: ...direction of the bolt without any play up to the edges of the strikers of the boltwork and tighten up the retaining screws The position must be selected such that the sliding striker of the boltwork runs over the entire opening path on the slanted sliding surfaces of the bolt and when fully open on the bolt head Tighten up the retaining screws so as to ensure a permanent and secure hold The screw ...

Page 5: ...e VdS approval is restricted to operation with input units of the Primor FS FL RO and RE series Connection of an analog keypad As supplied only the interface for an analog keypad from the Primor series is active If the lock is to communicate with a digital input unit i e an intelligent one then additional settings are required in the setup menu 6 in addition to the selection of the corresponding i...

Page 6: ...nction test after completing all the mounting and installation work With the door open you should open and close the lock several times using the master code that had been set at the factory The relationship between easy opening and reliable closing can be set via the operating lever of the boltwork The locking check can be done via the operating lever of the boltwork and should be performed after...

Page 7: ...s indicated by a long signal tone and the function test is terminated The system must be checked System setup The setting options and the control sequences that are required are described in the user manual We therefore recommend the following procedure Setup of the users menu 1 if applicable parameterisation of the inputs and outputs menu 6 if applicable setting up the Dualcode condition menu 6 i...

Reviews: