Anchor 4000
Installer manual
Installation and commissioning instructions
en_A4000-Teil 2-Errichterhandbuch V2.03.docx
6 / 7
Connection P- signal plus / UART
Connection via the second port (see above)
is always done if
the lock system has an external
power supply,
a "silent alarm" contact for
evaluation by an alarm system has
been made available,
a system block by an external
signal (dry contact) is to be used.
Additional hardware is required to do this.
The lock is compatible with all the available
components of the Primor series.
You can find information on the wiring in the
instructions for the signal box. The VdS
approval is no longer valid when used in
conjunction with a signal box or if the serial
interface (UART) is not used correctly.
Function test
Carry out a function test after completing all
the mounting and installation work. With the
door open, you should open and close the
lock several times using the master code
that had been set at the factory.
The relationship between easy opening and
reliable closing can be set via the operating
lever of the boltwork.
The locking check can be done via the
operating lever of the boltwork and should
be performed after each closing and
locking.
Input of the opening code
e.g. factory code Master
=
→
The opening code can be input
directly as described above, without
selection. After a valid code is input
the lock releases the bolt
movement for around 3 seconds.
Open the container with the
valuables within this time after
inputting the code.
=
If a signal block with "active release" (switching logic) has been set up this ensures that the
blocking is not switched off if the control cable is cut through. At the same, a cable breakage
within the safe always thus entails the risk of a blockade.