background image

Anchor 4000 

Installer manual  

Installation and commissioning instructions  

en_A4000-Teil 2-Errichterhandbuch V2.03.docx 

6 / 7 

 

 

Connection P- signal plus / UART

Connection via the second port (see above) 
is always done if 
 

  the lock system has an external 

power supply, 

  a "silent alarm" contact for 

evaluation by an alarm system has 
been made available,  

  a system block by an external 

signal (dry contact) is to be used. 

Additional hardware is required to do this.  
 
The lock is compatible with all the available 
components of the Primor series. 
You can find information on the wiring in the 
instructions  for  the  signal  box.  The  VdS 
approval  is  no  longer  valid  when  used  in 
conjunction with a signal box or if the serial 
interface (UART) is not used correctly.

 

 

 

 

 

Function test 

Carry out a function test after completing all 
the mounting and installation work. With the 
door open, you should open and close the 
lock  several  times  using  the  master  code 
that had been set at the factory.  

The relationship between easy opening and 
reliable closing can be set via the operating 
lever of the boltwork.  
The  locking  check  can  be  done  via  the 
operating lever of the boltwork and should 
be  performed  after  each  closing  and 
locking.  

Input of the opening code  

e.g. factory code Master





 

 
 

 

 

=

 

 

 

 

 

The opening code can be input 
directly as described above, without 
selection. After a valid code is input 
the lock releases the bolt 
movement for around 3 seconds. 
Open the container with the 
valuables within this time after 
inputting the code.  

 

 

 

=

 

 

 

If a signal block with "active release" (switching logic) has been set up this ensures that the 

blocking is not switched off if the control cable is cut through. At the same, a cable breakage 

within the safe always thus entails the risk of a blockade. 

 

 

Summary of Contents for Anchor 4000 Series

Page 1: ...neral 2 Preparation for installation 3 Installation dimensions 3 Preparation of the boltwork door 3 Installation 4 Wiring installation 5 Connection of an analog keypad 5 Connection P signal plus UART 6 Function test 6 Input of the opening code 6 Keypad test 7 System setup 7 Mount the keypad before installing the electronic lock All the keypads of the Primor series can be used Details on installing...

Page 2: ... the electronic lock in the area of the cutouts in the safe door It is essential that the lock is protected against attacks from outside We recommend that you protect against access the security relevant parts of the high security lock also when the door of the container that holds the valuables is open It is not permissible to use two locks of the same type in connection with analog keypads witho...

Page 3: ...on of the boltwork door For installation of the lock there must be three threaded holes with 5 mm screw in depth for attachment to the boltwork or within the safe door The electronic lock is to be attached with the supplied M6 or 1 4 screws or cylinder screws minimum strength class 8 8 The length of the screws must be 25 mm or more so that a minimum screw in depth of 5 mm is attained ...

Page 4: ...direction of the bolt without any play up to the edges of the strikers of the boltwork and tighten up the retaining screws The position must be selected such that the sliding striker of the boltwork runs over the entire opening path on the slanted sliding surfaces of the bolt and when fully open on the bolt head Tighten up the retaining screws so as to ensure a permanent and secure hold The screw ...

Page 5: ...e VdS approval is restricted to operation with input units of the Primor FS FL RO and RE series Connection of an analog keypad As supplied only the interface for an analog keypad from the Primor series is active If the lock is to communicate with a digital input unit i e an intelligent one then additional settings are required in the setup menu 6 in addition to the selection of the corresponding i...

Page 6: ...nction test after completing all the mounting and installation work With the door open you should open and close the lock several times using the master code that had been set at the factory The relationship between easy opening and reliable closing can be set via the operating lever of the boltwork The locking check can be done via the operating lever of the boltwork and should be performed after...

Page 7: ...s indicated by a long signal tone and the function test is terminated The system must be checked System setup The setting options and the control sequences that are required are described in the user manual We therefore recommend the following procedure Setup of the users menu 1 if applicable parameterisation of the inputs and outputs menu 6 if applicable setting up the Dualcode condition menu 6 i...

Reviews: