Preparation for installation
Installation dimensions
Preparation of the boltwork / door
For installation of the lock there must be
three threaded holes with 5 mm screw-in
depth for attachment to the boltwork or
within the safe door. The electronic lock is
to be attached with the supplied M6 or 1/4"
screws or cylinder screws (minimum
strength class 8.8).
The length of the screws must be 25 mm or
more so that a minimum screw-in depth of
5 mm is attained.