background image

Electromagnetic Cabinet Lock

Installation Instruction Guide

PRODUCT DIMENSION (unit : mm)

Caution :

1.  Do not over tighten the screw of armature plate when fixed because proper elasticity should be guaranteed for

the rubber washer so the armature plate should be adjust itself to the appropriate position.

2. It is recommended that to apply a light coat of silicon lubricant to the mating surface on a monthly basis to

prevent rust.

3. Connect the power wires accordance with NFPA 101 & all wiring to be completed inside protect area.

Spec

Model

Holding Force

Voltage Input

Dimension

Up to 140lbs  (64 kg)

12VDC / 24VDC

(L)69 x (W)38 x (T)27 (mm)

Current Draw

200mA / 100mA

140-S

68

32

10

38

27

69

WIRING INSTRUCTION

RED

ORANGE

WHITE

BLACK

DC 12V +

DC 12V

 -

Copyright 

©

 

EBELCO 

Industries Sdn. Bhd.

All Right Reserved 2022.

Pg 1/2

RED

ORANGE

WHITE

BLACK

DC 12V +

DC 12V

 -

Before the power supply is switched on, set the wiring correctly.

IMPORTANT NOTICE: