TK
+
ATEX
Appendix
Revision: 05
2022-D034859
en-43
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
≤ 68
Max. permissible housing
temperature [°C]
+80
Ambient temperature [°C]
See Chapter 10.4 "Specifications for startup and operation"
Lubrication
synthetic gear oil (see also Chapter 7.1 "Maintenance schedule")
Direction of rotation
In- and output opposite directions
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive;
Bore diameter of the
clamping hub: 38 mm
16.8 14.8 12.9 12.3 11.2 10.9 10.3 10.1 10.0 9.93
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive;
Bore diameter of the
clamping hub: 48 mm
31.5 29.5 27.6 27.0 25.9 25.6 25.0 24.8 24.7 24.6
a
No-load running torques diminish during operation
b
Refers to the center of the output shaft or flange
Tbl-30: TK
+
110, 2–stage: Technical data for use in potentially explosive atmospheres
Technical specifications for TK
+
110, 2-stage
Ratio i
12
16
20
25
28
35
40
50
70
100