Appendix
TK
+
ATEX
en-30
2022-D034859
Revision: 05
10.4
Specifications for startup and operation
10.4.1 Mounting position
Ambient temperature
Product type
Minimum temperature
[°C]
Maximum temperature
[°C]
TK
+
0
+40
Operating temperature
Product type
Max. permissible housing temperature [°C]
TK
+
+80
Tbl-19: Ambient temperature / Operating temperature
Improper use can cause damage to the gearbox and cause ignition hazards.
Ensure that the gearbox is mounted in the mounting positions depicted below to
ensure the lubrication of all gearbox components. In the case of application
conditions and mounting positions that differ from those depicted below (e.g.
inclinations around an axis of these mounting positions), place contact our
Customer Service department.
Mounting position B5/V3 (output shaft horizontal, motor shaft upwards)
Mounting position V1/B5 (output shaft downwards, motor shaft
horizontal)
Mounting position V3/B5 (output shaft upwards, motor shaft horizontal)
Mounting position B5/B5 (output shaft horizontal, motor shaft
horizontal)