VX 52 B / VX 53 B series
RF amplifier - single output stage
(1)
Input
configuration
(TP1)
Input test port
(bidirectional)
(2)
Input
diplexer
(10)
Upstream
amplifier module
(5)
Output
diplexer
(TP3)
Output
test port
(6)
Output
configuration
(TP2)
Test port
„US amp out“
Upstream hardware features.
Flip open the shielding on the right side for access to the output modules.
4.3.1 Input and output diplexer modules
Sockets
(2)
and
(5)
WISI
type
Description
Notes
-
Surge protection filter
(Downstream only)
pre-equipped in standard types
XE 50 B 0650
Diplex filter 65 / 85 MHz
pre-equipped in
VX 52 B CC / VX 53 B CC,
VX 52 B CH01 / VX 53 B CH01
XE 50 B 0850
Diplex filter 85 / 108 MHz
XE 50 B 2040
Diplex filter 204 / 258 MHz