3. Wiring Recommendations
Wiring should be installed, terminated, and tested for connectivity before the
camera is installed. Specifications for each connection are detailed below.
3.1. Wiring Connections
12V DC
Power In
BNC
Video Out
RS485 Leads
1. Power (Required)
It is recommended to install the camera power supply near the recording
location and run a remote power wire to the camera. Use the voltage drop
calculator at www.SnapAV.com to find the correct gauge for a given length
of wire.
Pinout
Wire Size (AWG)
Power Requirements
+
—
Minimum 18 AWG
Calculate based on
voltage & wire length
12V DC or 24V AC
(1A minimum)
Included WPS-ACC-PWR-M is illustrated to demonstrate the correct polarity for power.
2. BNC Video Output (Required)
Install coaxial cable for transmitting video to a DVR or display monitor.
Recommended Cable
Connector Type
RG-59 or RG-6
75-ohm rated BNC connectors
Use a BNC-RCA adapter for composite input
3. RS485 Communi/- Wires (Optional)
Connect the RS485 wires to a controller or a Wirepath DVR to enable remote
access to the OSD Setup Menu.
Pinout
Wire Size (AWG)
Camera
Controller
Minimum 24 AWG
2 Cat5e/6 conductors or 2-conductor alarm wire is
recommended
+
(White)
+
(Positive)
-
(Green)
-
(Negative)
Important!
Separate and insulate the ends of the RS485 wires if they will not be
connected.
DO NOT
connect the + and - wires together.