23
WPS-550-DOM-A Installation Manual
© 2013 Wirepath Surveillance
• NEG. IMAGE: The Negative Image View offers a wider dynamic
range and preserves most detail as it displays data exactly as
the CCD sees it. Select ON for the Negative Image View
mode to reproduce images with the most light intensity and
color information.
COMM ADJ
The communication adjustments can be
used to remotely control the camera’s OSD
(On Screen Display) from a PTZ controller or
DVR through RS-485. This is helpful for adjusting
camera settings after installation without
having to be next to the camera.
CAM ID
Select a unique ID number from 0 to 225.
Warning: If multiple cameras and devices are being used in the
surveillance system, confirm that no other device is using
the same ID. If two or more devices share the same ID number,
the PTZ controller or DVR will not be able to control or
configure any of the devices.
BAUD RATE
Choose a baud rate for RS-485 communication between the camera
and controller. Baud rate options include 4800, 9600, 19200, 38400, and
57600, and must be set to the same rate in all of the devices.
Warning: Confirm that all devices in the system use the same Baud Rate
PROTOCOL
Select a communication protocol of PELCO-D or PELCO-P.
Warning: Confirm that all devices in the system use the same protocol.
DISPLAY ID
• Set DISPLAY ID to ON to show the CAMERA ID on the screen.
This feature is useful when needing to know the ID of a camera
simply by viewing a picture.
COMM ADJ
CAMERA ID
001
BAUDRATE 4800
PROTOCOL PELCO-D
DISPLAY ID
OFF
ID POS
RETURN RET