Revision N
P/N 1002549
NOTE: Hand Pump Position Selector must be aligned for the same position as the Landing Gear Switch.
11. Gear Operation – VISUALLY VERIFY
If above procedure still fails to position landing gear as desired:
12. Landing Gear Motor Circuit Breaker – FULL.
13. Landing Gear Switch – DESIRED POSITION
14. Hand Pump Position Selector – PLACE IN DESIRED POSITION
15. Emergency Hand Pump – PUMP until resistance becomes heavy (may be 100 or more cycles)
16. Gear Position – CONFIRM VISUALLY
WARNING ! !
Do not attempt to land on water unless all four wheels are fully retracted.
17. Refer to Section 5.4 for more detailed troubleshooting.