background image

 

Version

 

0.2

1

 

Quick

 

start

 

i

DoorSensor

 

U

 

Technical

 

specs

 

Normal

 

operating

 

voltage

 

2x

 

AAA

 

1,5V

 

batteries

 

Frequency

 

range

 

ϵϬ

8.42

 

MH z

 

Wireless

 

Range

 

Up

 

to

 

30

 

meters

 

in

 

line

 

of

 

sight

 

Basic

 

Operations

 

 

The

 

iDoorSensor 

can

 

be

 

placed

 

on

 

any

 

door

 

or

 

window.

 

 

The

 iDoorSensor 

can

 

r

ep

ort

 

the

 

st

atus

 

of

 

the

 

door

 

(

O

P

E

N/CLOSED)

.

 

 

The

 

iDoorSensor 

can

 

mea

sure

 

the

 

temperature.

 

 

The

 

iDoorSensor 

also

 

has

 

an

 

external

 

contact.

 

Mounting

 

1.

 

Use

 

a

 

flat

 

screwdriver

 

at

 

the

 

inlets

 

on

 

the

 

sides

 

to

 

gently

 

unlock

 

the

 

back

 

cover.

 

2.

 

Use

 

the

 

designated

 

holes

 

on

 

the

 

back

 

cover

 

to

 

mount

 

the

 iDoorSensor

.

 

3.

 

Place

 

two

 

AAA

 

1,5V

 

batteries

 

into

 

the

 

device.

 

4.

 

Place

 

the

 iDoorSensor 

onto

 

the

 

back

 

cover,

 

be

 

sure

 

to

 

close

 

it

 

on

 

all

 

sides

 

 

and

 

that

 

the

 

tamper

 

gets

 

through

 

the

 

back

 

cover

 

of

 

the

 

iDoorSensor

 

(indication

 

mode:

 

Tamper

 

pressed/released).

 

5.

 

After

 

3

 

seconds

 

startup

 

routine

 

begins

 

(indication

 

mode:

 

Ready

 

for

 

learn

 

mode).

 

6.

 

After

 

5

 

more

 

seconds

 

(8

 

seconds

 

in

 

total)

 

mounting

 

is

 

completed.

 

(indication

 

mode:

 

Mounting

 

successful)

 

7.

 

i

D

oorSensor

 

is

 

no

w ready to use.

8.

 

Remove

 

the

 

back

 

cover

 

of

 

the

 

magnet

 

and

 

repeat

 

step

 

2

 

and

 

4

 

with

 

the

 

magnet

 

for

 

mounting

 

it.

  

Include

 

or

 

exclude

 

in

 

Z

­

Wave

 

network

 

1.

 

Make

 

sure

 

your

 

Z

Wave

 

controller

 

is

 

in

 

the

 

right

 

operation

 

mode

 

(include

 

or

 

exclude).

 

2.

 

When

 

the

 iDoorSensor 

is

 

mounted,

 

remove

 

it

 

from

 

the

 

back

 

cover

 

as

 

explained

 

in

 

step

 

one

 

of

 

the

 

Mounting

 

instructions.

 

3.

 

Press

 

and

 

hold

 

the

 

tamper

 

switch

 

for

 

1

 

se

c

ond

 

an

d

 

re

l

e

a

se

 

to

 

st

a

r

t

 

the

 

inclusion

 

or

 

exclude

 

process

 

(indication

 

mode:

 

Ready

 

for

 

learn

 

mode).

  

4.

 

 

(The

 

product

 

will

 

start

 

NWI

 

automatically

 

after

 

unsuccessful

 

normal

 

inclusion)

 

Indication

 

mode

 

The

 

indicator

 

light

 

gives

 

various

 

statuses

 

of

 

the

 

device

 

as

 

follows:

 

1.

 

Ready

 

for

 

learn

 

mode:

   

indicator

 

light

 

blinks

 

every

 

second.

 

2.

 

Learn

 

in

 

progress

 

(add):

 

indicator

 

light

 

2

 

times

 

every

 

second.

 

3.

 

Learn

 

in

 

progress

 

(remove):

 

indicator

 

light

 

3

 

times

 

every

 

second.

 

4.

 

Learn

 

mode

 

success:

   

indicator

 

light

 

is

 

on

 

for

 

one

 

second.

 

5.

 

Learn

 

mode

 

failed:

 

 

indicator

 

light

 

blinks

 

8

 

times

 

rapidly.

 

6.

 

Tamper

 

pressed/released

 

indicator

 

light

 

blinks

 

3

 

times

 

rapidly.

 

7.

 

Mounting

 

successful

    

indicator

 

light

 

is

 

on

 

for

 

1

 

second.

 

External

 

contact

Magnet

Indicator

 

Light

 

Tamper

 

switch

Summary of Contents for iDoorSensor

Page 1: ... successful 7 iDoorSensor is now ready to use 8 Remove the back cover of the magnet and repeat step 2 and 4 with the magnet for mounting it Include or exclude in Z Wave network 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the iDoorSensor is mounted remove it from the back cover as explained in step one of the Mounting instructions 3 Press and hold the...

Page 2: ...SIC_TYPE_ROUTING_SLAVE Generic type GENERIC_TYPE_SENSOR_BINARY Specific type SPECIFIC_TYPE_NOT_USED Listening False Z Wave Lib 4 51 class 0x30 COMMAND_CLASS_SENSOR_BINARY class 0x70 COMMAND_CLASS_CONFIGURATION class 0x71 COMMAND_CLASS_ALARM class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class 0x80 COMMAND_CLASS_BATTERY class 0x84 COMMAND_CLASS_WAKE_UP class 0x85 COMMAND_CLASS_ASSOCIATION class 0x8...

Page 3: ...ps Retries The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops class 0x20 COMMAND_CLASS_BASIC When a door is opened a basic set frame with the value 255 is sent to the associated ...

Page 4: ... mode Mode 3 Z Wave chip is always on to request e g version or manufacturer id If any mode other then 3 that value will be reported after a get but will be handled in SW as mode 1 Param2 3 not used 6 The temperature offset Description A offset for the temperature Default 0x00 Size 2 bytes Param1 2 A signed integer to determine the offset off the temperature Param3 4 not used if a size is other th...

Page 5: ... will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is 0xFF 255 broadcast It is possible to send a wake up notification on user interaction To do this press and hold the tamper switch for 8 seconds When the wake up time is set to 0 a wake up notification is never send periodically only on...

Page 6: ...Even when a configuration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x...

Page 7: ...try it again 2 Make sure the Tamper switch is mounted correctly 3 The magnet contact is not mounted close enough or on the wrong side of the device Q I have configured a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during conf...

Page 8: ......

Reviews: