External dosing devices
39
Connecting an external detergent dosing device
Example 1:
Hose pump with time-delay
relay and fixed output
Example 2:
Hose pump with adjustable
output
Example 3:
Hose pump with fixed output
(e. g. ESP 166, ESP 166C,
SP 166Z)
Connect to WASH terminal.
Set time-delay relay on the
dosing device.
Connect to FILL terminal.
Set P704=1.
Set output on the dosing
device.
Connect to FILL terminal.
Set P704=2.
Set both potentiometers to
maximum.
Set dosing amount on the
machine.
If the capacity is not equal to
166 ml/min, set P706 (see
service instructions).
Connecting an external rinse aid dosing device
Example 1:
Hose pump with adjustable
output
Example 2:
Hose pump with fixed output
(16 ml/min) (e.g. SP 16K )
Connect to RINSE terminal.
Set P709 = 0.
Set output on the dosing
device.
Connect to RINSE
terminal.
Set P709=2.
Set potentiometer to
maximum.
Set dosing amount on the
machine.
16.3 Setting parameters
Retrieving the settings
Tap the following buttons in turn:
Type in "1575"
INFO
Incorrectly entered digits
can be corrected with the
button.
1
Parameters
(P704 = detergent; P709 = rinse aid)
2
Scroll keys for switching between
P704 ↔ P709
3
Parameter value
4
Scroll keys for setting the parameter
value
5
Confirm input
6
Back button