27
Procedures
Required material:
Kit softener
Item no. 83000420
Item no. 83000421 (Japan)
Tool:
Ring wrench 60003376
Important note:
The machine must be de-installed
Note for UC-S
The procedures also apply for the UC-S.
However, it is not required to de-install the
boiler
Observe the safety notes on page 7
Remove the front panel
Pull the suction pipes out of the chemical containers
Put the suction pipes into a measuring cup with water
Successively activate the dosing devices in the actor programme
in order to rinse them with water
Drain the tank
Switch the machine free of voltage
De-install the machine
Remove the right side panel
Remove the right stiffener wall
Completely drain boiler
Remove the left stiffener wall together with the dosing devices
Pull off the pressure hoses off the dosing devices
Pull off the plug of the dosing devices
Pull off the thermo sensor of the tank
Unplug and de-install the drain pump
Summary of Contents for UC-L
Page 1: ...Winterhalter Undercounter Dishwashers UC Series Repair manual ...
Page 10: ...8 Exchange collector ...
Page 12: ...10 Exchange collector continuation ...
Page 14: ...12 Exchange collector continuation ...
Page 16: ...14 Exchange boiler heating element ...
Page 18: ...16 Exchange boiler ...
Page 22: ...20 Exchange tank heating element ...
Page 24: ...22 Exchange pump head dosing device Fluidos ...
Page 26: ...24 Exchange dosing device Fluidos ...
Page 28: ...26 Exchange integrated water softener ...
Page 30: ...28 Exchange integrated water softener continuation ...
Page 32: ...30 Exchange heat exchanger radial fan ...
Page 34: ...32 Exchange heat exchanger radial fan continuation ...
Page 46: ...44 ...
Page 47: ......