Winnix Technologies co., Limited
4/12
2) card-reading sense twin pole mode technology
3) card-reading time: single tag 54ID no.
<
6ms
3) Operation voltage: DC+9V
4) Operation temperature:
-
20
℃
~
+80
℃;
5) Storage temperature:
-
40
℃
~
+125
℃
Second: the Configuration and Interface Instruction
1 every part of reader instruction
Picture1 Configuration Instruction of HYR6021A
1) instruction of every part of the reader
Derivation instruction of the reader
The derivation line instruction of the reader
Mainframe of the reader
The stationary barrier of the reader
2) interface instruction of the reader
The hookup of HYR6021A
interface
Electricle
source
RS232
RS485
TRIGGER
WIEGAND
Color
red
black
white
purple
gray
brown
yellow
orange
green
blue
pink
green
Define
+9V
GNE
TX
RX
GND
A+
B-
TRIGGER
GND
DATA0
DATA1
GND
2. Instruction of the interface
2.1 RS232
The reader provide RS232 communication interface for connecting communication with control
mainframe((commonly the PC machine),the data format of the RS232 interface is 8 data bits, a star
bit and a stop bit, without parity bit; 9600
,
19200
,
38400
,
57600 and 115200 are the choices for data
modulus.RS232 communication interface support the fitting parameter, demonstration program, all the
second exploitation bag function of the single communication of the reader.
2.2 RS485
:
Model A and B reader of DRF series provide RS485 communication interface,, which can connect with
Stationary barrier
Mainframe
Derivation line
Derivation