10-9
SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
Error Codes
When an error occurs during slideout room
operation, the slideout control panel (located in
driver side compartment) will use LED display
lights to indicate where the problem exists.
For specific motor faults, the green LED light
will blink 1 time for Motor 1 and 2 times for
Motor 2. The red LED light will blink from 2 to
9 times, depending on the error code. The error
codes are as follows:
•
(2) - BATTERY DROP OUT.
Battery
capacity low enough to drop below 6 volts
while running.
•
(3) - LOW BATTERY.
Voltage below 8 volts
at start of cycle.
•
(4) - HIGH BATTERY.
Voltage greater than
18 volts.
•
(5) - EXCESSIVE MOTOR CURRENT.
High amperage (also indicated by one side of
slideout room continually stalling).
•
(6) - MOTOR SHORT CIRCUIT.
Motor or
wiring to motor has shorted out.
•
(8) - HALL SIGNAL NOT PRESENT.
Encoder is not providing a signal. This is
usually a wiring problem.
•
(9) - HALL POWER SHORT TO
GROUND.
Power to encoder has been
shorted to ground. This is usually a wiring
problem.
NOTE: When an error code is present, the
slideout control panel needs to be reset.
Operating the Extend/Retract switch will
reset the slideout control panel. Operate
the Extend/Retract switch again for
normal operation.
Manual Override
In the event that the slideout room fails to
retract and manual operation is required:
•
Locate the slideout control panel (located in
driver side compartment).
•
Press the Mode button 6 times, quickly. Press
a 7th time and hold for approximately 5
seconds.
Red and green LED lights will begin to flash,
confirming the override mode.
•
Release Mode button.
•
Use the slideout control switch (located inside
the coach) to retract the room.
NOTE: If slideout room fails to retract using the
Manual Override method, see “Slideout
Emergency Retraction” elsewhere in this
section.
Further Information
See the slideout room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
SLIDEOUT EMERGENCY
RETRACTION (POWER GEAR
®
)
IN WALL SLIDEOUT
–If Equipped
If the slideout mechanism is malfunctioning
and the room will not retract using the interior
control switch, see the In Wall Slideout Room
operating guide included in your InfoCase for
further instructions and troubleshooting
information.
Slideout Room Controller
(Located in a driver or passenger side
compartment, depending on model)
- Remove panel to access
• Status
LED’s
• Motor
Direction
• Mode
Button
• Motor 1
Connection
• Motor 2
Connection