![background image](http://html1.mh-extra.com/html/winnebago/2013-adventurer/2013-adventurer_operators-manual_987453119.webp)
10-9
SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
4. Crank the room(s) until it is just “snugged up.”
Do not over-crank or you could damage the
gear assembly.
5. While maintaining pressure on ratchet
wrenches, re-engage the motor brake by
moving lever clockwise slightly - or to right
when facing end of motor (repeat for motor at
other end of room, if equipped).
6. Reconnect motor power lead to wiring
harness (repeat for motor at other end of room,
if equipped).
7. Fasten slideout room travel latching device (if
equipped) inside the coach before driving the
vehicle.
8. See your dealer for service of the slideout
mechanism before using again.
Further Information
See the Slideout Room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
SLIDEOUT EMERGENCY
RETRACTION (LIPPERT)
-If Equipped
If the slideout mechanism is malfunctioning
and the room will not retract using the interior
control switch or exterior control panel, you may
need to access the slideout motors and manually
push the room in to the travel position.
There are two slideout motors equipped on the
end wall of each slideout room. Pull back wipe
seal to access motors.
Push-In Procedure
1. Remove slideout motor retention screw
(located along exterior slideout trim), if
equipped.
Repeat on opposite slideout trim.
NOTE: If your coach is not equipped with
slideout motor retention screws, proceed
to Step 2.
2. Pull back wipe seal to access slideout motor.
3. Using a flat-head screwdriver, push bottom of
slideout motor UP to disengage
(approximately 1/2” from base).
Repeat on opposite slideout motor.
Slideout Motor Retention Screw
(Located along exterior slideout trim)
-If Equipped
Slideout Motor
(Located behind slideout wipe seal)
• Use a screwdriver to push slideout motor
UP (disengage).