![Winmate M700DM4 Standard Operation Procedure Download Page 22](http://html1.mh-extra.com/html/winmate/m700dm4/m700dm4_standard-operation-procedure_987191022.webp)
STANDARD
OPERATION
PROCEDURE
(DO NOT COPY OR DISTRIBUTE W ITHOUT PERMISSION) FMRD33B
22
Part No
98TF07MA4001
Revision
100
S
tation
Operation Name
LCD
&
I/O
Test
Remark
Steps Test Description:
1
Evaluate the brightness adjustment.
2
Use Micro SD 32GB or more then test if it
functions properly.
3
Insert Micro USB to evaluate into PC test
machine.
4
Use Micro USB OTG cable to connect the
mouse.
5
Using Finger separate capacitive stylus and
Touch accessories.
Item Judgment Standard:
1
required at least 425nit brightness
2
Micro SD must read properly
3
PC must able to recognize and transfer file
to the test machine.
4
OTG must function properly.
5
Touch must function properly <need to
touch the correct position>
Item Tools:
1
Brightness
2
32GB above Micro SD
3
Micro USB Cable
4
Micro USB OTG Cable
5
9B0000000326 Capacitive Touch Stylus
Item Note:
1
STEP 1~5
STEP 1~5