Page 34

Winkhaus STV

Oper

ating Manual EA

V 0124653 0505

Subject to technical changes

Winkhaus STV GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · Germany · www.winkhaus.de · [email protected]

Errors/Causes/Troubleshooting

Error

Indication

Possible cause

Troubleshooting

the door does not 

lock automatically

hooked locking 

tongue possibly not 

locked

•  the door is warped

•  the contact pressure is too 

high

•  the door has not been 

installed properly

•  check the installation, if 

    required the strikes

•  adjust the hinge plates

the latch is 

“blocked”

the door is not 

closed in the center 

range

•  the cut-out in the area of 

the main locking house 

is possibly not sufficient 

(dimensions see page 14)

•  recut, if necessary

the door cannot be 

closed

the tracer is “blo-

cked” at the single 

strike

•  the door sash has not been 

mounted properly

•  at the single strike
 

 change the height of 

the door striker (by using a 

screw driver)

the motor does not 

function although 

voltage is applied 

at the door

the door cannot be 

opened

•  no voltage supply via the 

cable transition

•  check the cable transition 

  (e. g. contacts, screwed joint 

for KÜ-T STV)

the door cannot 

be opened by the 

motor

the motor does not 

function

•  power failure

•  power supply is interrupted, 

e. g. at the cable transition

•  unlock mechanically via 

    profile cylinder/handle or 

    lock via profile cylinder

•  check KÜ (correct the plugin 

    connection) or see above

the motor stops

•  the door is warped

•  the contact pressure is too 

high

•  the lock is too tight 

•  adjust the door

•  check the soft movement 

via profile cylinder/handle

the motor functions 

but the door cannot 

be opened

•  the main bolt is unlocked 

via profile cylinder

•  draw the main bolt back 

again via the profile cylinder

Power failure

when/during:
a)  the door is 

locked

•  the door can be operated 

mechanically (profile cylin-

der/handle)

b)  the door is 

open, lock is 

unlocked

the door is possibly 

not held by the 

latch

•  the motor is not in starting 

position

•  close the door by pre-

locking the main bolt, if 

necessary

c)  the unlocking 

procedure 

when the door is lo-

cked again, possibly 

the M-hook, main 

bolt do not lock 

completely

•  the motor is not in starting 

position

•  door can be operated 

mechanically (profile cylin-

der/handle), if motor has 

returned to starting position

  

 completely functions

6. Errors/Causes/Troubleshooting

Summary of Contents for AV2

Page 1: ... Operating Manual Electronic Automatic Locking System After installation please pass on these instructions to the end customer according to the Information Disclo sure Act stipulated in the Law on Product Liability ...

Page 2: ... following information and graphic images provided correspond to the current status of the development and manufacture of this product For the purpose of customer satisfaction and operational reliability of the electronic automatic locking system we reserve the right to make changes to this product All information and specifications given in this operating manual have been compiled and reviewed wit...

Page 3: ... General connection diagram 17 3 4 Access control system transponder set 18 3 5 Access control system wireless remote control 20 3 5 1 Wireless remote control set 20 3 5 2 Wireless receiver separate 22 4 Operation Programming 24 4 1 Electronic automatic locking system 24 4 1 1 Locking and unlocking 24 4 2 Electronic automatic door locking system with transponder 24 4 2 1 Operation 24 4 2 2 Program...

Page 4: ...and 60 C The complete door fittings are designed to be used in conjunction with the genuine Winkhaus parts Other parts which are not recommended by Winkhaus can adversely affect the default properties of this locking system We shall assume you use the lock as intended The proper functions of the access control systems and of the accessory equipment included in the scope of delivery of the Winkhaus ...

Page 5: ... promoting air compositions require special door furniture The locking systems are incorrectly used that is use contrary to the one described above is evident in particular if the instructions on the intended use are not being followed the problem free operation is hindered due to the installation of external objects and or objects that are not purpose conform in the opening zone the locking sys t...

Page 6: ...s are used to identify important information in this operating manual Cues such as DANGER or CAUTION indicate the degree of hazard Symbols serve to visually emphasize the message It is imperative that you do follow the measures listed to avoid safety hazards DANGER Danger of life or danger of serious injuries CAUTION Danger of material damage NOTICE Useful information and tips ECO WATCH Notices on...

Page 7: ...s The manufacturer shall only be held liable for security related properties of the locking system as stipulated within the bounds of statutory regulations if the manufacturer himself or another instructed authorized agent has carried out the maintenance and service work or made the changes Winkhaus STV shall not be liable for any type of damage caused by inadequate repair or changes made 1 6 Abbr...

Page 8: ...oduct description The electronic automatic locking system is a state of the art locking unit for securing and locking entry doors in a contact free manner Easy to use and convenient All ope ning and closing members of the locking mechanism are power driven In the external zone around the entry door Figure 2 1 Electronic automatic locking system with accessories 2 Product description ...

Page 9: ...X X 2 Motor box X X 3 Extension keep set single strike X X 4 Center strike FRA X X 5 5 1 5 2 Cable transition KÜ T STV Cable at the sash side 2 m 2 187 yd or 2 5 m 2 734 yd long plug for motor box included Cable at the frame side 4 m 4 374 yd long X X 6 Power supply 12 V DC 1 A X 7 Access control system shown antenna of the transponder set NOTICE Only install the antenna of the transponder set in ...

Page 10: ...57 7 AV2 F 2060 55 92 8 M2 rs ls mc 123 558 6 123 559 5 AV2 F 2060 55 92 8 M2 rs ls gr 124 074 9 124 075 8 AV2 F 2060 55 92 10 M2 rs ls mc 123 891 2 123 892 1 AV2 F 2060 60 92 10 M2 rs ls mc 123 560 2 123 561 1 AV2 F 2060 65 92 8 M2 rs ls mc 123 562 0 123 563 9 AV2 F 2060 65 92 10 M2 rs ls mc 123 564 8 123 565 7 AV2 F 2460 35 92 8 M2 rs ls mc 123 566 6 123 567 5 AV2 F 2460 40 92 8 M2 rs ls mc 123 ...

Page 11: ...r retrofitting simply screwing to the automatic locking system Caution Pay attention to left handed thread 2 if an automatic locking system motor box EAV mounted are simultaneously ordered supply of the locking system with mounted motor box 3 incl signal floating contact for swing door opener NOTICE Please observe the following instructions when using a swing door opener Ensure that the motor can op...

Page 12: ...RS or LS 4 Center strike FRA Center keep for latch and dead bolt of plastics aluminum and wooden entryway doors Select the respective keeps also according to the profile systems in the current program manual see above 5 Cable transition KÜ T STV Plug in and concealed cable transition plugable by plug in function with retaining screws sash element with spring jacket and cable of 2 m 2 187 yd or 2 5 ...

Page 13: ...remote control Transponder set EAV Consisting of 1 reader control unit for flush type box 1 antenna for exposed installation 90 x 90 x 13 mm 3 543 x 3 543 x 0 512 color white cable of 2 5 m 2 734 yd fixed at the antenna 1 antenna sticker weatherproof resistant to UV light 3 transponder chips key tags color blue have not been taught 2 programming card transponders programming card green delete all ca...

Page 14: ...Cutting diagrams For installing the electronic automatic locking system it is required to cut out a standard three point locking system and additionally the motor box as shown in the following figures NOTICE Important for wooden entry doors Please enlarge the cut out for the additional locking houses up to 47 mm 1 850 Figure 3 1 1 Dimensions for the electronic automatic locking system 3 Installatio...

Page 15: ...tic locking system Figure 3 1 3 Situation of the main locking house for the electronic automatic locking system NOTICE a The cut out for the main locking house must be 16 mm 0 630 as mini mum to provide the free motion of the drive rod Check the door fitting groove for cleanness so that the free motion of the rod is not limited b It is recommended to use it always with a so called alternate furnitu...

Page 16: ...through the door sash Insert the end of the spring into the hole in the door sash Fasten the element in the fitting nut by using the fitting screws 2 having a of 4 x 25 mm 0 984 Install the cable for example within the glass groove towards the motor box install the rest of the cable for example within the hollow cell 3 2 Cable transition KÜ T STV plug in Installation sequence NOTICE Provide a cable ...

Page 17: ...y assemble and install only with the power off CAUTION It must be easily possible to lock the door mechanically only then check the electric function If you connect an intercom system take care that the button of this system is designed as a floating contact External voltage must not be transmitted from the intercom system to the lock If the operating voltage has been applied start up the motor bri...

Page 18: ... the reader unit DANGER For safety reasons you are not permitted to install it in a flush type box with a 230 V switch or socket outlet The transponder antenna is located in a housing in exposed installation and is to be installed in a weatherproof zone outside the entry door Do not mount the antenna directly on metal as its range could be decreased drasti cally Do not mount any other antenna withi...

Page 19: ...tr 6 D 98617 Meiningen Germany www winkhaus de stv winkhaus de No Terminals 1 12 V DC 2 0 V DC 3 serial interface 4 serial interface 5 antenna 6 antenna 7 floating contact C 8 floating contact NO Figure 3 4 1 Terminal assignment of the transponder reader Figure 3 4 2 Installation of the transponder reader 3 Installation ...

Page 20: ...CE If you use the flush type box of the button the box will have to be 65 mm 2 559 deep Unless you use a switch or button beside the door you will have to provide a flush type box with a filler panel for the wireless receiver DANGER For safety reasons you are not permitted to install it in a flush type box with a 230 V switch or socket outlet Connect the terminals 2 through 5 of the wireless receiver ...

Page 21: ...ct to technical changes Winkhaus STV GmbH Co KG Berkeser Str 6 D 98617 Meiningen Germany www winkhaus de stv winkhaus de No Name 8 P1 key 9 green LED 10 red LED 11 buzzer 12 relay 13 jumper 12 V 24 V Figure 3 5 1 2 Installing the wireless receiver 3 Installation ...

Page 22: ...a the jumper NOTICE Check the proper position of the jumper before starting operation 3 5 2 Wireless receiver separate Separate wireless receiver for additional applications such as garage door control units Figure 3 5 2 1 Installing the wireless receiver Installation sequence Remove the cover of the housing Fasten the housing with screws Push in the rubber plug see Figure 3 5 2 1 Insert the circu...

Page 23: ...transmitter 11 12 12 V AC DC 11 13 24 V AC DC 14 Antenna 15 Screen Figure 3 5 2 2 Terminal assignment of the circuit board of the receiver No Name 1 JP1 jumper 2 P1 key 3 K4 relay 4 red LED 5 green LED You can set the K4 relay as ON OFF or as an impulse via the JP1 jumper see figure 3 5 2 3 The setting depends on the control unit which is to be triggered by the receiver Relay becomes briefly active ...

Page 24: ... main dead bolt for additional protection must be unlocked by keys in any case Opening the door from inside e g via the button the intercom floating contact button the handle or key even possible in case of power failure 4 2 Electronic automatic door locking system with transponder 4 2 1 Operation The reader unit controls and monitors the access to the door It is operated by means of transponders t...

Page 25: ...d Action Acoustic Signal Result Door with transponder Open short long not authorized If you do not swipe the transponder chip across the antenna for a period of 5 seconds the teach in mode will be stopped The reader unit returns to operating mode 4 2 2 Programming Each transponder set is supplied with 2 programming card transponders programming card green delete all card red These cards are taught...

Page 26: ...no more transponders can be tutored memory over 250 transponders have already been programmed Delete mode Delete all card Delete mode All transponders Deletes all transponders key tags Gesamt Lösch Karte CAUTION By using the delete all card all the transponders stored in the system will be deleted The action of deleting all transponders is irrevocable once the process has been completed You have t...

Page 27: ...mer service in such a case 4 3 Electronic automatic locking system with wireless remote control 4 3 1 Operation It is operated via the wireless hand held transmitters working contactless The set of 3 wireless hand held transmitters delivered have already been taught key A To trigger a signal press the A key of a taught in hand held transmitter The red LED will turn on and the door will be unlocked...

Page 28: ...ive continuous signal is briefly interrupted pressed key s is are taught in If no hand held transmitter has been taught for example after delete all func tion it would apply to all hand held transmitters The teach in mode can be started with any hand held transmitter Deleting wireless hand held transmitters directly via the hand held trans mitter Partial deletion Action Acoustic Signal Result 1 Pre...

Page 29: ... batteries NOTICE Pay attention to the correct polarity ECO WATCH Properly dispose of the batteries as demanded by environmental regulation NOTICE Keep the keys pressed until you can hear the acoustic signal Delete all Action Acoustic Signal Result 1 Press keys A and B of a tutored hand trans mitter simultaneously short teach in mode started 2 Press A key of the same hand transmitter continuous si...

Page 30: ...led to capacity max 85 keys if the teach in key of a new wireless hand held transmitter is used and both LED displays of the receiver flash simultaneously Deleting wireless hand held transmitters directly via the receiver Partial deletion Press and hold the P1 key of the receiver until the green LED lights up Release the key Press the key of the wireless hand held transmitter while the LED is lit u...

Page 31: ... press the P1 key of the receiver until the green LED lights up Release the key again Press the P1 key once more The LED flashes and the relay is switched to the ON OFF mode Use the same procedure to get to the pulse mode Then the LED will be lit continuously Displaying the occupied memory units Press and hold the P1 key of the receiver until the green LED lights up Keep the key pressed until the L...

Page 32: ...2 seconds When the green LED lights up release the P1 key Press the key of the wireless hand held transmitter you would like to delete The deletion of the key is signalized by the flashing LED Delete all Press and hold the P1 key until the green LED lights up Release the P1 key When the LED lights press the P1 key again until both LEDs flash three times The memory is full once 85 keys have been save...

Page 33: ...be replaced Check the locking mechanism and smooth operation of the security lock at regular intervals at least once every three months At least once a year more frequently if under a higher stress factor all moveable parts and all accessible sliding members of the locking system need to be lubricated with Vaseline and checked for proper performance regarding mechanics and electro nics You should ...

Page 34: ...check the cable transition e g contacts screwed joint for KÜ T STV the door cannot be opened by the motor the motor does not function power failure power supply is interrupted e g at the cable transition unlock mechanically via profile cylinder handle or lock via profile cylinder check KÜ correct the plugin connection or see above the motor stops the door is warped the contact pressure is too high t...

Page 35: ...consumption max 100 mA Voltage 12 V AC DC 7 2 Wireless remote control Receiver type Superheterodyne Modulation AM ASK Frequency 433 92 MHz Number of code combinations 2 to the power of 64 Rolling Code Frequency of the local oscillator 6 6128 MHz Intermediate frequency 10 7 MHz Sensitivity to receive signals 115 dB Input impedance 50 ohm Maximum memory capacity max 85 keys Power supply 12 24 V AC D...

Page 36: ...ulation AM ASK Frequency 433 92 MHz Frequency of the local oscillator 6 6128 MHz Intermediate frequency 10 7 MHz Sensitivity to receive signals 115 dB Input impedance 50 Ohm Maximum memory capacity 85 codes for hand held transmitter Power supply 12 24 V AC DC Closed circuit current 15 mA On load current 33 48 mA Number of relays 1 NO NC Power 24 W Dimensions 80 x 80 x 50 mm 3 150 x 3 150 x 1 969 7...

Page 37: ... 4 form key tag color blue Transponder chip T01 blue 123 131 2 Wireless hand held transmitter Wireless hand held transmitter separate as an extension to the wireless remote control set 123 775 3 color dark gray gray Wireless hand held transmitter F01 dark gray 123 133 0 Wireless receiver Wireless receiver separate e g for coupling with the garage door control unit the second key at the hand held t...

Page 38: ...rectives established and stipulated by the Council on the Harmonization of Legal Regulations of Member States regarding Electromagnetic Compatibility 89 336 EEC The following standards have been applied to assess the electromagnetic compatibility of the product Emitted interference according to EN 61000 6 3 Immunity to interference according to EN 61000 6 2 This declaration is made on behalf of th...

Page 39: ...Page 39 Winkhaus STV Operating Manual EAV 0124653 0505 Subject to technical changes Winkhaus STV GmbH Co KG Berkeser Str 6 D 98617 Meiningen Germany www winkhaus de stv winkhaus de ...

Page 40: ...Page 40 Winkhaus STV Operating Manual EAV 0124653 0505 Subject to technical changes Winkhaus STV GmbH Co KG Berkeser Str 6 D 98617 Meiningen Germany www winkhaus de stv winkhaus de ...

Reviews: