![WinGD X92-B Operation Manual Download Page 373](http://html1.mh-extra.com/html/wingd/x92-b/x92-b_operation-manual_986582373.webp)
2
Release the pressure of the servo oil supply unit to 0 bar.
3
) from the defective fuel pump (003). Refer to
the Maintenance Manual for more information.
4
Install the flange (002) to the fuel pump (003).
5
Install the flange (007) to the intermediate piece (006).
6
Remove the applicable cover (005) from the supply unit casing (004).
NOTE:
Make sure that the applicable supply unit cam is at TDC and if not do
.
Fig 10-6
Roller lifting tool assembly
7
Operate the turning gear to turn the supply unit cam at TDC to push the roller (001,
) of the guide piston (002) at the highest position.
8
Tighten the elastic bolt (003) with the pad (004).
9
Tighten the round nut (005) until it touches the pad (004).
10
Make sure that the pad (004) touches the guide piston (002).
X92-B
AA00-5556-00AAB-510B-A
Operation Manual
Fuel pump - cutting out
Winterthur Gas & Diesel Ltd.
- 373 -
Issue 002 2021-11