11
1. WHITE
2. PURPLE
3. BLUE
4. GREEN
5. YELLOW
9. BLACK
8. BROWN
6. ORANGE
7. RED
CAUTION!
Improper alignment of connector plug can cause system failure. USE
EXTREME CARE when making connection. Unit MUST BE DISCONNECTED
FROM POWER SOURCE before connecting.
How to test voltages when checking electronics
Measuring voltages present at wall plate control
will aid in determining damaged circuitry in
electronics housing.
Set voltage meter to DC and touch black meter lead (-)
on meter to #9 screw terminal on wall plate connector.
(Black wire - ground)
Touch red meter lead (+) to each of the colored wires
listed below.
Symptom: Unit may not park.
1.
White
wire voltage range 4.8 VDC - 5 VDC.
(4.7 would indicate damaged circuitry in the
electronics housing — replacement of electronics
housing needed.)
Symptom: Unit may fail to rotate or elevate.
2.
Purple
wire voltage range 4.8 VDC - 5 VDC.
(4.7 would indicate damaged circuitry in the
electronics housing — replacement of electronics
housing needed.)
3 - 6.
Blue, green, yellow, orange
. These wires
should measure .5 VDC or 1.8 VDC, depending on
LED states.
7.
Red
wire will read supply voltage to the unit when
wall plate is switched on.
8.
Brown
wire will read primary voltage supplied to
unit (11 to 13.8 VDC)
9.
Black
wire is ground.