41
Additional Remote Interface:
Prior to adding an additional remote interface to the system, you will have to change setting 30
on the first control to give it a different address. Refer back to page
30
for instructions on how to
access the interface Settings, and get to Setting 30 (shown on page 36).
Controller Specification
Application
WG only, single stage cooling or heating
Humidification
Programmable
No
Change over
Auto or manual, Fan ON or AUTO
Color
Black (only)
User interface
Touch screen
Auto defrost control
Yes, with Serving temp option
Connection
Communicating
–
RJ-9 cable
Wireless-to-base communication range
40’ line of site
Wireless-to-base channels
12
Remote sensors
Yes, wired or wireless
Temperature adjustment
34 to 97 Deg F (1 to 36 Deg C)
Temperature tolerance
+/- 2 Deg F (+/- 1.1 Deg C)
Humidity adjustment
2% to 93% RH
Humidity tolerance
+/- 10% RH
System temperature diagnostics
Not Available
Alarms
High temp, low temp.
High humidity, low humidity.
High pressure fault.
Condensate, Defrost and Communication error