To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com
MAINTENANCE
86039020 VOYAGER E 08/20/07
4-4
TROUBLESHOOTING
CONDITION
CORRECTIVE
ACTION
No Power to
Machine
Faulty power cord
Replace
Power switch failure
Replace if necessary.
Internal wiring problem
Have a trained service technician inspect and
repair the machine.
Electrical Shock
Equipment not
grounding
Follow grounding instructions exactly.
Receptacle not
grounded
Have an electrician inspect the building’s wiring.
Internal electrical
problem
Have a trained service technician inspect and
repair the machine.
Nuisance Tripping of
Brush Circuit
Breaker
Brush “buried” in carpet
Brush is adjusted to low, adjust position using
Brush control lever. Best cleaning results are
achieved with minimal brush/carpet contact.
Faulty circuit breaker
Replace if necessary.
Mechanical
problem
Higher amp draws may indicate a mechanical
problem. Find parts which are not moving freely
and repair or replace.
Vacuum Motor
Speed Varies or
Doesn’t Run
Worn motor brushes
Replace
Faulty
switch
Replace
Faulty circuit breaker
Replace
Internal wiring problem
Have a trained service technician inspect and
repair the machine.
Loss of Vacuum
Loose dome
Center dome over tank.
Crack in dome or poor
joint
Replace or repair using acrylic plastic cement
only.
Damaged Dome Gasket
Replace
Lint or dirt clogging
vacuum intake screen
With power off, clean vac intake screen found in
dome.
Accessory tool clogged
Clean out tool, ensure free air flow.
Internal electrical
problem
Have a trained service technician inspect and
repair the machine.
Machine does not
propel
Belt tension handle on
“Neutral”
Put belt tension handle in “Drive” position.