Maintenance
Do not use a pressure washer to clean around the brush motors. Use tap pressure only.
N’utilisez pas de nettoyeur haute pression pour nettoyer autour des moteurs des brosses. Utilisez
seulement la pression du robinet.
To Replace Scrub Brush Motor - Disk
With the scrub deck in the lowered position, disconnect brush motor wiring connector from harness.
1. Disconnect the two(2) connectors from solenoid valve.
2. Remove squeegee.
3. Remove front bumper.
4. Remove four (4) front bolts connecting deck lifting arms to front of machine.
5. Lift deck and side deck lift brackets off actuator lifting pin.
6. Slide deck out from under machine on right side, orientation is determined from operators view.
7. Remove brush/pad.
8. Remove driver.
9. Remove three (3) screws securing brush motor to deck.
10. Remove brush motor.
11. Reverse steps to install.
To Replace Scrub Brush Motor - Orbital
With the scrub deck in the lowered position, disconnect brush motor wiring connector from harness.
1. Disconnect electrical connections.
2. Remove squeegee.
3. Remove front bumper.
4. Remove four (4) front bolts connecting deck lifting arms to front of machine.
5. Lift deck and side deck lift brackets off actuator lifting pin.
6. Slide deck out from under machine on right side, orientation is determined from operators view.
7. Remove pad driver.
8. Remove counterweight and orbital mechanism.
9. Remove four (4) bolts mounting motor to deck frame.
10. Remove motor.
11. Reverse steps to install.
86398220 Operators Manual - Chariot-2 iScrub 20